80
■
General condition: ALC
Sets the conditions related to whole file.
Setting / Readout data of general condition
STX
ALC
Sub
command
[X offset] [Y offset] [Z offset] [Rotation offset]
[Overwriting frequency] [Overwriting interval]
[Flip (Y axis symmetry)] [Flip (X axis symmetry)]
[2D/3D selection]
Max. 41-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of general condition
STX
ALC
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
X offset
8
Model type*
Setting range [mm]
LP-Sxx0(W)
“-045.000”–“+045.000”
LP-Sxx5(W)
“-080.000”–“+080.000”
LP-Sxx2
“-027.500”–“+027.500”
LP-Mxx0/LP-Zxx0 “-060.000”–“+060.000”
LP-Mxx5
“-110.000”–“+110.000”
LP-Mxx6/LP-Zxx6 “-165.000”–“+165.000”
Y offset
8
Z offset
(Effective only
LP-M / LP-Z
series)
8
Model type*
Setting range [mm]
LP-Sxxx(W)
“+000.000”
LP-Mxxx
“-022.000”–“+022.000”
LP-Zxxx
“-025.000”–“+025.000”
•
LP-Sxxx/LP-SxxxW:
As this item is not available for the
LP-S series, set to “+000.000”.
•
LP-Mxxx/LP-Zxxx:
The marking position is offset to the
Z direction.
Rotation offset
7
“-180.00”–“+180.00” [°]
Overwriting
frequency
4
“0001”–“9999” [times]
Marking is repeated by the repeat
number set. When the marking on the
flying object is valid, set “0001”.
Overwriting
interval
3
“0.0”–“9.9” [sec] or “010”–“060” [sec]
The interval period at overwriting
marking is set.
Flip (Y axis
symmetry)
1
“0”: Inversion OFF
“1”: Inversion ON
The character marked is inverted to the
Y axis.
Flip (X axis
symmetry)
1
“0”: Inversion OFF
“1”: Inversion ON
The character marked is inverted to the
X axis.
2D/3D
selection
(Effective only
LP-M / LP-Z
series)
(1)
•
LP-Sxxx(W)
“0”
•
LP-Mxxx/LP-Zxxx
“0”: 2D marking
“1”: 3D marking
•
LP-Sxxx/LP-SxxxW:
As this item is not available for the
LP-S series, set to “0” or no data.
•
LP-Mxxx/LP-Zxxx:
Selects 2D/3D marking.
* For the detail of the model type, refer to “Target laser marker” (P.4).
Reference
• When marking on the flying object is valid, Overwriting Function cannot be used.
ME-LPMSZ-SR-9
Содержание LP-M Series
Страница 8: ...1 Before External Control ME LPMSZ SR 9...
Страница 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Страница 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Страница 165: ...Troubleshooting ME LPMSZ SR 9...
Страница 186: ...Character Code Table ME LPMSZ SR 9...
Страница 199: ...Index ME LPMSZ SR 9...
Страница 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Страница 203: ...No 9000 0063 59V...
Страница 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...