41
■
Marking status transmission permission: MST
Enables automatic response of marking result (e.g. normal end, and error occurrence, etc.) at the end of marking.
Setting / Readout data of marking status transmission permission
STX
MST
Sub
command
[Transmission permission/prohibition]
1-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of transmission permission/prohibition of response
STX
MST
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Transmission
permission/
prohibition
1
“0”: Transmission prohibited
“1”: Transmission permitted
Data transmission after setting marking status transmission permission
The status is transmitted if the marking failure occurs when marking is normally completed or when character string is set
outside the marking area transmission permission when receiving a marking trigger by the serial communication command
after marking status transmission permission is set.
STX
MST
A
[Status] [Marking energy measurement]
[Marking energy value]
14-byte (LP-Mxxx / LP-Sxxx), 4-byte (LP-SxxxW/LP-Zxxx)
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Status
4
“0000”: Marking is normally completed.
“E001”–“E999”: Error code at marking operation
The status after marking
operation is indicated.
Marking energy
measurement
(Effective only
LP-Mxxx /
LP-Sxxx)
(1)
“0”: Marking energy correct
“1”: Marking energy incorrect
“2”: Determination impossible
(when an error other than E710 occurs or after
the power check or laser power measurement
completes.)
Not transmitted for LP-
SxxxW/LP-Zxxx.
Marking energy
value
(Effective only
LP-Mxxx /
LP-Sxxx)
(9)
“000000100”–“999999999” [mJ]
It is valid in the correct operation and E710. In other
cases, “000000000” is indicated.
Reference
•
When marking status function is used, set the transmission permission before every shifting to the remote mode.
•
When the remote mode is released, the marking status transmission is returned to the transmission prohibition.
•
For the error code at marking operation, refer to “Error Indication” (P.178).
ME-LPMSZ-SR-9
Содержание LP-M Series
Страница 8: ...1 Before External Control ME LPMSZ SR 9...
Страница 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Страница 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Страница 165: ...Troubleshooting ME LPMSZ SR 9...
Страница 186: ...Character Code Table ME LPMSZ SR 9...
Страница 199: ...Index ME LPMSZ SR 9...
Страница 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Страница 203: ...No 9000 0063 59V...
Страница 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...