177
Others
Troubles
Causes
Measures
Laser is emitted at
unintended timing.
Photoelectric sensor for marking trigger
signal malfunctions.
Fumes may cause malfunction of photoelectric
sensor for marking trigger signal.
•
Install dust collector.
•
Check that dust collector works well.
Date is reset.
Internal battery has run out.
Contact failure may also be a cause of this
symptom. When laser marker have been in use
for five years or more, internal battery is easy to
run out.
Contact our sales office for replacement of
internal battery.