13
User's Manual
after five
6. Display Modes
6-1 Normal State
• This product has the following three mode views:
Normal state,
Remaining battery level, and
Operation
mode.
• The
Normal state displays the operating status of the system (stopped, grid operation, Stand-alone operation, etc.)
as well as error codes in the event of system problems.
• The
Remaining battery level displays the current remaining capacity of the storage battery.
• The
Operation mode view displays the currently selected operation mode (Maximum self-consumption mode /
Programmed charge/discharge time mode / Stand-alone mode).
• Press "DATA (▲)" to switch between the display modes.
*
*
Remaining battery level and
Operation mode views automatically return to the
Normal state
minutes of
inactivity.
Depending upon the battery’s
condition the battery might
not be able to be discharged
down to 0%.
* Order to carry out the re-calculation of the remaining amount of the battery, there is a case where the value of the remaining
amount is not continuously changed.
* The mode views can be switched while the system is operating or stopped.
Normal state
Remaining battery level
Operation mode
Display of the status of battery
SELF : Maximum self-consumption mode
ProG : Programmed charge/discharge
time mode
bu : Back-up mode
rc : Remote control mode
dr : DRED mode
The following information is displayed in the normal state:
Stopped (Grid-connected)
Stopped via User’s command.
If "ON/OFF (CANCEL)" is
pressed for one second,
the system will start the grid
operation.
Inspection Notice
System shows the Inspection
notice. Period until inspection
added.
(See 10-3)
Stopped (Stand-alone)
Stopped via User’s command.
"PF" will display.
If "ON/OFF (CANCEL)" is
pressed for one second, the
system will start the
stand-alone operation.
In Operation
(Stand-alone)
The system in stand-alone
operation, indicates output
power and "PF".
If "ON/OFF (CANCEL)" is
pressed for one second, the
system will stop.
In Operation (Grid-connected)
The system in grid operation
display indicates charge or
discharge power.
If "ON/OFF (CANCEL)" is
pressed for one second, the
system will stop.
Error
The system has abnormally
stopped and indicates error
mode (F/H/U/P/E) and code.
you confirm the time.
to fine-tune
to fine-tune the storage battery. Abnormal
7. Date/Time Display and Setting
7-1 Date/Time Display
• Press "CLOCK (▼)" in the normal state to check the current date/time.
• The current year => month/day => hour/minute will each be displayed for two seconds.
• The control panel display will automatically return to the normal state after displaying the current hour/minute.
* This product uses the date/time data to control the charging/discharging and
operations may result if the date/time is incorrect. Be sure to check the date/time setting on a periodic basis.
* If there is an error between the date/time setting and the actual date/time, refer to 7-2 Date/Time Setting to set the date/time
correctly.
7-2 Date/Time Setting
• Press "CLOCK (▼)" for three seconds in the normal state to switch to the date/time setting mode.
• Each time you press "Menu (ENTER)", the active item will change in the order of year => month => day => hour =>
minute.
The active setting value blinks.
• Press "DATA (▲)" and "CLOCK (▼)" to change the value of the blinking digit.
• Set the minute and press "MENU (ENTER)" to complete the date/time setting.
• Once the date/time setting is complete, the set date/time data will be displayed in the order of year => month/day
=> hour/minute for two seconds each and then the normal display will be automatically returned to.
* This product uses the date/time data to control the charging/discharging and
the storage battery.
Abnormal operations may result if the date/time is incorrect. Be sure to set the date/time accurately.
* If not linked with the network adaptor, an error may occur in the date/time data depending on the precision of the internal clock
of the storage battery system. Once a month, it is recommended that
To maintain normal operations of the battery system, you are advised to check the date/time setting on a periodic basis.
* When linked with the network adaptor, the date/time setting is automatically updated by a server via the network adaptor.
* The product's time might deviate about 60 seconds per month. If this builds up, it will affect the electric bills.
Adjust the time in conjunction with checking the time once per month.
1 sec
Normal State
Automatic
Automatic
Month/Day
Hour/Minute
Year
Automatic
Date/Time Display
* Press
"
DATA (▲)
"
and
"
CLOCK (▼)
"
to change the value.
Date/Time Setting (7-2)
Year
Month
Day
Hour
Minute
3 sec