1
1-11-99
SELECTING THE INSTALLATION SITE (Type F1)
Indoor Unit
AVOID:
areas where leakage of flammable gas may be expected.
places where large amounts of oil mist exist.
direct sunlight.
locations near heat sources which may affect the
performance of the unit.
locations where external air may enter the room directly.
This may cause “condensation” on the air discharge ports,
causing them to spray or drip water.
locations where the remote controller will be splashed with
water or affected by dampness or humidity.
installing the remote controller behind curtains or furniture.
locations where high-frequency emissions are generated.
DO:
select an appropriate position from which every corner of the
room can be uniformly cooled.
select a location where the ceiling is strong enough to
support the weight of the unit.
select a location where tubing and drain pipe have the
shortest run to the outdoor unit.
allow room for operation and maintenance as well as
unrestricted airflow around the unit.
the limitation of the tubing length between the indoor and
the outdoor units should be referred to the Installation
Instructions of the outdoor unit.
allow room for mounting the remote controller about 1m off
the floor, in an area that is not in direct sunlight or in the flow
of cool air from the indoor unit.
25 cm
40 cm
65 cm
25 cm
HOW TO INSTALL THE INDOOR UNIT
Low Silhouette Ducted Type (Type F1)
Required Minimum Space for Installation and Service
This air conditioner is usually installed above the ceiling so that the indoor unit and ducts are not visible. Only the air intake and air
outlet ports are visible from the unit bottom.
Minimum space for installation and service
Type
60, 71
100, 125, 140
A (Length)
1,067
1,467
636
33.4
33.4
B
D
C
D
154
(150)
54
700
30
290
255
15
140
23
23
113
65
70
90
26.1
300
186
27
256
172
280
g
h
f
i
c
d
b
a
e
j
Unit: mm
Type
A
B
C
D
E
F
60, 71
1,067
1,000
750 (Pitch 150 × 5)
21
792
16
100, 125, 140
1,467
1,400
1,050 (Pitch 150 × 7)
71
1,192
20
Unit: mm
Air intake port side
Air outlet duct side
F
-ø3 holes
E
(Flange O.D.)
A
(Suspension bolt pitch)
a
) Refrigerant tubing joint (liquid tube)
b
) Refrigerant tubing joint (gas tube)
c
) Upper drain port VP25 (O.D. 32 mm)
200 mm flexible hose supplied
d
) Bottom drain port VP25 (O.D. 32 mm)
e
) Suspension lug (4 – 12 × 30 mm)
f
) Power supply outlet
g
) Fresh air intake port (ø150 mm)
h
) Flange for flexible air outlet duct
i
) Electrical component box
j
) Filter
Inspection
access
450 × 450
(Field supply)
Unit: mm
A
(Suspension bolt pitch)
Min. 250
Electrical
component box
Inspection
access
450 × 450
Refrigerant
tubing
Min.650
Indoor unit
Min.400
Min.
250
636
Unit: mm
It is recommended that space be provided (450 × 450 mm) for checking and servicing the electrical system.
Detailed dimensions of indoor unit
SM830266-00_大洋州向けR32シングルTD&SM.indb 99
18/03/29 10:21:12
Содержание Inverter R32 Series
Страница 93: ...1 10 10 1 SM830266 00_ R32 TD SM indb 10 18 03 29 10 19 58...
Страница 94: ...1 10 11 1 SM830266 00_ R32 TD SM indb 11 18 03 29 10 19 58...
Страница 95: ...1 10 12 1 SM830266 00_ R32 TD SM indb 12 18 03 29 10 19 59...
Страница 96: ...1 10 13 1 SM830266 00_ R32 TD SM indb 13 18 03 29 10 20 00...
Страница 241: ...MEMO 1 13 11 SM830266 00_ R32 TD SM indb 11 18 03 29 10 21 37...