1-10-18
1
1
Type K2
Earth Wiring
Make the earth wiring 25 - 30 mm longer than power cable.
Power Supply
Power Cable
Remote Control Wiring
Ground terminal fixing for
(
: Functional earthing)
Inter-unit Control Wiring
If the terminal screws on the terminal board are tightened
too hard, the screws might be damaged. See the tightening
torque values as shown below.
Tightening torques for
terminal screws
1.0 – 1.4 N · m
{10 – 14 k
g
f · cm}
Type E1
Type T2
Functional ground screw
(Schedule Timer)
Earth Wiring : Make the earth
wiring 25 - 30 mm longer than
power cable.
Remote Control Wiring
Power cable
Clamp
Power wiring
Use this screw when connecting the shield for the Inter-unit control wiring to ground.
Protective ground screw
Inter-unit Control Wiring
Power inlet port
Clamp
Remote control wiring and inter-unit control
wiring inlet port
* Insert the remote control wiring and
inter-unit control wiring into the electrical
component box from the inlet port as shown
in the figure. This is done regardless of
whether the wiring was inserted from the
top, rear, or left side of the main unit.
( : Functional earthing)
How to carry out power supply wiring
(1) Wiring connection ports
The power inlet port is located at the rear.
The remote control wiring inlet port is located at the rear
(for use with the wired remote controller). For details,
see the figure under the section 3-1 (3).
(2) How to carry out wiring
Insert the power wiring into the indoor unit through the
rubber at the side of the electrical component box.
For wiring connection to the outdoor unit and remote
control wiring, open the elongated hole of the piping
cover and pass the wires through the hole.
NOTE
Be sure to use sealing putty to seal off the opening to
prevent dust.
Type F1
Use this screw when connecting the shield
for the Inter-unit control wiring to ground.
Functional ground screw
Protective
ground screw
Earth Wiring :
Make the earth wiring 25 - 30 mm longer than power cable.
Power
Supply
Power cable
Inter-unit
Control
Wiring
Remote
Control
Wiring
(
: Functional earthing)
R1 R2 U1 U2
N
L
Shielded
wire ground
Remote
controller
line
Unit
control
wiring
Power
suppy
Earth
SM830266-00_大洋州向けR32シングルTD&SM.indb 18
18/03/29 10:20:02
Содержание Inverter R32 Series
Страница 93: ...1 10 10 1 SM830266 00_ R32 TD SM indb 10 18 03 29 10 19 58...
Страница 94: ...1 10 11 1 SM830266 00_ R32 TD SM indb 11 18 03 29 10 19 58...
Страница 95: ...1 10 12 1 SM830266 00_ R32 TD SM indb 12 18 03 29 10 19 59...
Страница 96: ...1 10 13 1 SM830266 00_ R32 TD SM indb 13 18 03 29 10 20 00...
Страница 241: ...MEMO 1 13 11 SM830266 00_ R32 TD SM indb 11 18 03 29 10 21 37...