Introducing GTWIN
GTWIN Reference Manual
54
Item
Description
Set GT station no.
Set the GT station no. to which you wish to transfer the GT configuration.
Be sure to assign the station no. 0 to one GT unit!
Control device
The address where information regarding GT link is stored (see "How GT
Link Functions" on p. 55).
Priority mode
In both cases, writing to the PLC always has high priority, and the GT must
obtain the token before it can communicate.
Display priority
. each GT station completes all command and
response operations necessary for its screens before passing the token
to the next station.
Operation priority
: the GT station processes 1 operation at a time,
then passes the token to the next station.
Momentary switch
You can select whether pressing a momentary switch establishes
exclusive communication between that GT station no. and the PLC. During
"exclusive communication", there is no communication with other GT
stations.
Exclusive communication with PLC
when operating touch switch
You can select whether pressing any touch switch establishes exclusive
communication between that GT station no. and the PLC for the time
specified. During "exclusive communication", there is no communication
with other GT stations.
Display message in stand-by mode
Until the station obtains the token, it is in "stand-by mode" and cannot
communicate. Activating this option displays a message indicating this.
Содержание GTWIN
Страница 1: ...TOUCH TERMINALS GTWIN Reference Manual ...
Страница 11: ...Chapter 1 Introducing GTWIN ...
Страница 59: ...Chapter 2 GT Panel System Menu ...
Страница 94: ...Chapter 3 The GTWIN User Interface ...
Страница 108: ...Chapter 4 Menus ...
Страница 182: ...Chapter 5 Parts and Their Functions ...
Страница 234: ...Chapter 6 Troubleshooting ...
Страница 248: ...Chapter 7 Connecting the GT to a PLC ...
Страница 277: ...Connecting the GT to a PLC GTWIN Reference Manual 276 Wiring diagrams For GT with RS485 interface ...
Страница 281: ...Connecting the GT to a PLC GTWIN Reference Manual 280 For GT with RS485 interface and FP X COM4 ...
Страница 286: ...GTWIN Reference Manual 7 13 Connecting Via GT Link 285 Wiring diagrams For GT with RS485 interface and FPG COM3 ...
Страница 287: ...Connecting the GT to a PLC GTWIN Reference Manual 286 For GT with RS485 interface and FPG COM4 ...
Страница 288: ...Chapter 8 SD Card Data Upload from GT to PC ...
Страница 293: ......