Notes :
1. The total maximum memory available for the sequence program area size and machine language
program area size is 10K words for the FP3.
2. The value of address No.5 and 6 must be the same. The Set(Preset) value area(SV) and the
Count(Elapsed) value area(EV) are also Hold/Non-hold according to the set value of No.6.
3. Each holding area is divided by the word number you use. The area from 0 to the number specified
is Non-hold, and from that number to the end is Hold. To set the whole area hold operation, use a
number which is 1 word larger than the maximum.
4. Set addresses No.30 to 32 as.shown below.
Set time = Set value x 2.5ms(Set value is decimal.)
The default value are set as shown below.
Address No.30...default value: 120(set time: 300 ms)
Address No.31...default value:2,600(set time: 6.5 s)
Address No.32...default value: 800(set time: 2.0 s)
5. Set the address No.33 as below.
Set time=Set value x 2.0
µ
s(Set value is decimal.)
The default value: 5,000(set time:10 ms)
6. The terms “Hold” and “Non-hold” are specified as;
* Hold area: the memory area whose contents will be lost or modified if the operating power is lost.
* Non-hold area: the memory area whose contents will be lost or modified if the operating power is
lost.
6-3. Table of FP3/FP5 System Registers
82
Number
Description
Default value
Settable range
Remote I/O Operating Mode Setting
35
Confirmation for connection of a slave station
1(Set)
0:Release
1:Set
36
Selection of Remote I/O update method
0
0:Synchronous
1:Asynchronous
Setting for P/W Link 0
40
Link data register memory size
0
0 to 128 words
(0 to 1,024 points)
42
Link relay send
Starting words No.
0
0 to 63
43
memory size
No. of words to be sent
0
0 to 64 words
44
Link data register Starting words No.
0
0 to 127
45
send memory size No.r of words to be sent
0
0 to 127 words
46 to 49
Unused
Setting for P/W PL Link 1
50
Link relay memory size
0
0 to 64 words
(0 to 1,024 points)
51
Link data register memory size
0
0 to 128 words
52
Link relay send
Starting words No.
64
64 to 127
53
memory size
No. of words to be sent
0
0 to 64 words
54
Link data register Starting words No.
128
128 to 255
55
send memory size No. of words to be sent
0
0 to 127 words
59 to 59