
5-1. Self-diagnostic Errors
56
5-1.Self-diagnostic Errors
The W Type(Wire) Link Unit has hardware self-diagnostic functions to check errors in the W Type(Wire) Link
Unit.
Since the hardware diagnostics are performed right after the power is turned ON, the W Type(Wire) Link Unit will
be activated only when no hardware error is detected.
When a Hardware Self-diagnostic Error is Detected
1.Both the ERROR 1 and ERROR 2 LEDs flash.
2.Turn OFF the power once and check the unit by switching the power ON and OFF several times.
3.If the error is detected(that is, both the ERROR 1 and ERROR 2 LEDs still flash), a hardware error may occur
in the unit. Replacement of the faulty W Type(Wire) Link Unit is recommended.
[Unit Start-up Flowchart]
Turn ON the power
Is the W Type(Wire) Link Unit
in normal condition?
Hradware self-diagnosis
Setting
Is the Mode Selector
Switch 1(MODE SW. 1)
set to OFF.
PC Link Mode
Not in PC Link Mode
When a hardware self-diagnostic error occurs, both the
ERROR 1 and ERROR 2 LEDs flash.
NO
YES
NO
YES