5-43
Troubleshooting
U10
ADF (option) open
U11
Finisher copy paper removal
NOTE: When clearing U11, all
paper must be removed
from bins.
U12
Staple door/Top door open
1) Is ADF or ADF door closed correctly ?
2) Is ADF installed correctly ?
3) ADF connector is shorted or broken.
4) ADF door open/close sensor connector is
shorted or broken.
5) ADF door open close sensor is defective.
6) ADF CPU PCB connector is shorted or broken.
7) ADF CPU PCB is defective.
8) LVPS connector is shorted or broken.
9) LVPS is defective.
10) CPU PCB connector (
CN19
/
25
) is shorted
or broken. (FP-D250/D350)
11) Image processing PCB connector (
CN19
)
is shorted or broken. (FP-D450/D600)
12) CPU PCB is defective.
13) Image processing PCB is defective.
(FP-D450/D600)
1) Copy paper is already in at least one bin.
2) Copy paper which is unsuitable size for
stapler use is in the bin.
3) There is a double feed from the duplex unit
in the bin.
4) Finisher paper detecting sensor connector
is shorted or broken.
5) Finisher paper detecting sensor is defective.
6) Finisher CPU PCB connector is shorted or
broken.
7) Finisher CPU PCB is defective.
8) LVPS connector is shorted or broken.
9) LVPS is defective.
10) (FP-D250/D350)
CPU PCB connector (
CN15
) is shorted or broken.
(FP-D450/D600)
CPU PCB connector (
CN15
) is shorted or broken.
11) CPU PCB is defective.
1) Is the stapler door or top door closed correctly ?
2) Stapler door or top door open/close sensor
connector is shorted or broken.
3) Stapler door or top door open close sensor
is defective.
4) Finisher CPU PCB connector is shorted or broken.
5) Finisher CPU PCB is defective.
6) LVPS connector is shorted or broken.
7) LVPS is defective.
8) (FP-D250/D350)
CPU PCB connector (
CN15
) is shorted or broken.
(FP-D450/D600)
CPU PCB connector (
CN15
) is shorted or broken.
9) CPU PCB is defective.
Code
Item
Check points
Содержание FP-D350
Страница 198: ...4 77 PCB Connector and Signal Information 2 Control Panel PCB A FP D250 D350 Series CN354 CN355 Not used ...
Страница 332: ...4 211 PCB Connector and Signal Information 2 Control Panel PCB A FP D450 D600 Series CN354 CN355 Not used ...
Страница 517: ...5 79 Troubleshooting Code Item Function Factory setting US38 User information list 0 Stop 0 1 Start ...