3-39
Preventive
Maintenance
4)
Replacement of the discharge lamp.
(1)Open the front door.
(2)Swing open the toner hopper 180°.
(3)Remove 1 screw.
(4)Disconnect the harness.
(5)Remove the lamp holder.
(6)Remove the discharge lamp (Filter and 3
screws).
8
3)
Removal of the dust collecting filter
(1)Remove the copier rear and right side
covers.
(2)Remove the dust collecting fan motor
block.
(3)Remove the dust collecting filter.
7
3
4
5)
Removal of the drum separation finger
(1)Remove the drum unit.
(2)Disconnect the sensor harness.
(3)Remove the touch ring.
(4)Side the sensor base to rear side then
put it down and pull out.
(5)Remove the sensor PCB from under side.
(6)Push the from under side and slide the
separation finger then remove it.
Note: Be careful when removing and
reinstalling the drum finger that the two
springs are not lost or damaged.
(7)Reassemble in reverse order.
9
A
3
2
4
A
6
6
5
Содержание FP-D350
Страница 198: ...4 77 PCB Connector and Signal Information 2 Control Panel PCB A FP D250 D350 Series CN354 CN355 Not used ...
Страница 332: ...4 211 PCB Connector and Signal Information 2 Control Panel PCB A FP D450 D600 Series CN354 CN355 Not used ...
Страница 517: ...5 79 Troubleshooting Code Item Function Factory setting US38 User information list 0 Stop 0 1 Start ...