![Panasonic FP-D350 Скачать руководство пользователя страница 101](http://html.mh-extra.com/html/panasonic/fp-d350/fp-d350_user-manual_257132101.webp)
3-28
3)
Removal of the thermistor
4)
Removal of the separation fingers (upper/lower)
• Perform procedure 5.
(1) Remove the two screws.
1 2
(2)Remove the thermistor.
3
9
(1)Open the fuser exit door.
(2)Remove the screws (x 2).
(3)Remove the separation finger (upper)
bracket.
(4) Remove the separation fingers (upper)
springs.
(5) Remove the separation fingers (upper).
10
(1)Remove the screw (x1) and fuser exit
cover pin then remove the exit cover.
(2)Remove the screws (x 2).
(3)Remove the paper guide.
11
SV507
3
2
1
2
1
2
3
4
5
5
1
2
2