3-46
Location
Procedure
(3) Adjust
F6-84
as necessary using the steps
outlined below.
(4) If the distance between the left edge of
the paper and the nearest black line is less
than 5 mm input a positive number, using
the chart in the left as a reference.
(5) If the distance between the left edge of
the paper and the nearest black line is
more than 5mm, input a negative number,
using the chart in the left as a reference.
Contents
-4
-3
-2
-1
0
1
2
3
4
Function
Move 2.0 mm to the left
Move 1.5 mm to the left
Move 1.0 mm to the left
Move 0.5 mm to the left
0.0 mm
Move 0.5 mm to the right
Move 1.0 mm to the right
Move 1.5 mm to the right
Move 2.0 mm to the right
Location
Procedure
NOTE: ADJUSTMENT OF THE CCD UNIT
SHOULD ONLY BE PERFORMED
IF ALL PRINTER SECTION
ADJUSTMENTS HAVE BEEN
EXHAUSTED.
Image skew adjustment
(1)Scribe the CCD unit before loosening the
front screw.
(2)Loosen the front screw ONLY.
(3)Rotate the unit clockwise if the image skew
is similar to the image in diagram 1 left.
(4)Rotate the unit counterclockwise if the
image skew is similar to the image in
diagram 2 left.
4. Skew / Registration Adjustments (Scanner Section)
(Original)
Diagram 1
Diagram 2
Содержание FP-D350
Страница 198: ...4 77 PCB Connector and Signal Information 2 Control Panel PCB A FP D250 D350 Series CN354 CN355 Not used ...
Страница 332: ...4 211 PCB Connector and Signal Information 2 Control Panel PCB A FP D450 D600 Series CN354 CN355 Not used ...
Страница 517: ...5 79 Troubleshooting Code Item Function Factory setting US38 User information list 0 Stop 0 1 Start ...