30
MSU rear panel
3
1
5
7
9
11
AUX
CCU IN
CSU
BREAKER
DC 12V IN
POWER
2
4
6
8
10
12
43
42
41
40
39 38
38. DC power switch [POWER]
This sets the power of the main unit of the master setup
unit to ON or OFF.
39. DC 12 V input connector [DC 12V IN] (XLR 4
pins)
The model AW-PS550 AC adaptor (optional accessory) is
connected here.
When using other power sources, make sure the
output is DC 12 V ± 2 V, 5 A or more.
Note
Made by Hirose: HA16RX-4P(SW1)
Pin No.
Signal name
1
GND
2
NC
3
NC
4
DC 12 V
40. Circuit breaker [BREAKER]
This power supply circuit breaker is used in cases of
emergency.
41. CSU connector [CSU]
This connector is for future expansion.
Made by DDK: 57-20240-D35
Pin No.
Signal name
Pin No.
Signal name
1
Reserved
13
Reserved
2
Reserved
14
Reserved
3
Reserved
15
Reserved
4
Reserved
16
Reserved
5
Reserved
17
Reserved
6
Reserved
18
Reserved
7
Reserved
19
Reserved
8
Reserved
20
Reserved
9
Reserved
21
Reserved
10
Reserved
22
Reserved
11
Reserved
23
Reserved
12
Reserved
24
Reserved
Do not connect anything to the reserved pins.
Note
42. AUX connector [AUX]
This connector is for future expansion.
Made by Hirose:
HDEB-9S
Pin No.
Signal Name
1
Reserved
2
Reserved
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
Reserved
9
Reserved
Do not connect anything to the reserved pins.
Note
43. CCU connectors [1 to 12]
These connectors are for signal interfacing with the
camera control unit (AK-HCU355A, AK-HCU3550,
AK-HCU200).
Made by Hirose:
HR10A-10R-10P
Pin No.
Signal name
Pin No.
Signal name
1
CSU CONT(H)
6
TALLY G
2
CSU CONT(C)
7
HEAD POWER
3
CSU DATA(H)
8
ALARM1
4
CSU DATA(C)
9
ALARM0
5
TALLY R
10
GND
Parts and their functions
Содержание AK-MSU935AP
Страница 75: ...75 Memo ...