26
C
Auto setup switch [AUTO SET UP]
This switch is used to execute auto setup.
The setup status is output to the picture monitor.
“SETUP” selection options are provided on the FUNC
menu, and the OUT FULL or OUT EASY mode is set.
OUT FULL: Standard setup based on an outdoor
shooting chart
<Sequence of operation execution>
When the AK-HC3500A/AK-HC3500 camera
is used
AWB
ABB
BSHD
ABB
AWB
GAMMA
FLARE
BSHD
ABB
AWB
GAMMA
FLARE
AWB
When the AK-HC3800 camera is used
AWB
ABB
BSHD
ABB
AWB
FLARE
AWB
OUT EASY: Easy setup based on an outdoor
shooting chart
<Sequence of operation execution>
When the AK-HC3500A/AK-HC3500 camera
is used
AWB
ABB
AWB
GAMMA
FLARE
ABB
AWB
GAMMA
FLARE
AWB
When the AK-HC3800 camera is used
AWB
ABB
AWB
FLARE
AWB
Align the gray scale wedge position with the angle of
view in the vertical direction of the viewfinder.
Take care in selecting the position at which the chart is
shot since at some positions it may not be possible to
execute auto setup satisfactorily.
How to initiate auto setup
1. Press the auto setup switch.
2. The auto setup switch flashes at 2-second intervals,
the auto setup start preparation mode is established,
and a square marker appears in the center of the
camera’s viewfinder. Roughly align this square with the
white at the gray scale center.
(To cancel the setup, hold down the switch for at least
one second.)
3. When the auto setup switch is pressed again, its LED
lights, and auto setup begins.
(If the switch is pressed at any point during the auto
setup operation, auto setup will be aborted.)
4. If the auto setup is completed successfully, the LED of
the auto setup switch will be extinguished.
• If the LED flashes at 1-second intervals, it means that
the operation has been terminated without completing
the auto setup.
• During the auto setup operation, the operation status is
displayed using characters on the PM.
19. MONITOR
R
G
B
S E Q
E N C
MONITOR
Monitor selector switches [R, G, B, SEQ, ENC]
When the AK-HC3500A/AK-HC3500 camera is used
These are used to select what is to be displayed on the
waveform monitor (WFM) and picture monitor (PM).
The output mode can be changed by selecting the
MONI LINK settings on the SYSTEM screen.
If MONI LINK is set to ON, the monitor display is also
switched temporarily in linkage with the R, G and B
shading switches when BLACK SHADING and WHITE
SHADING are to be adjusted.
Monitor selector
switch
HDTV
SDTV
SDI4/PM
P-M
WFM
P-M
R
R
R
R
R
G
G
G
G
G
B
B
B
B
B
SEQ
RGB
Y
RGB
Y
ENC
RGB
Y
VBS
VBS
The R, G and B switches can be selected simultaneously.
The RGB outputs on the WFM display are shown as a parade display.
When the AK-HC3800 camera is used
This does not operate because the function is not
available.
The ENC switch is always lit.
20. Scene file switches [1 to 4, 5 to 8]
1
2
3
4
5
6
7
8
STORE
SCENE
FILE
When the AK-HC3500A/AK-HC3500 camera is used
These file selector switches enable up to 8 sets of data
to be stored ahead of time and then to be called when
the data is needed.
When the AK-HC3800 camera is used
These file selector switches enable up to 4 sets of data
to be stored ahead of time and then to be called when
the data is needed.
With AK-HC3800, scene file numbers 5 to 8 are not
available.
How to call scene file data
1. From among the 1 to 8 scene file switches, press the
number of the switch that corresponds to the scene file
which is to be called and light its lamp.
2. The scene file is now loaded. The data loaded from the
scene file is input into the current file and then output.
3. When the scene file has been loaded, the data left in
the current file until that moment is temporarily saved.
The lamp of the scene file switch remains lighted even
after the data has been called.
To stop calling the scene file, press the scene file switch with
the lighted lamp to turn its lamp off. The setting information
that was temporarily saved before the scene file was called
is now returned to the current file, and the setting statuses
established prior to the scene file call are also restored.
Parts and their functions
Содержание AK-MSU935AP
Страница 75: ...75 Memo ...
Страница 76: ...Web Site http panasonic net Panasonic Corporation 2013 ...