150
Maintenance and Inspections: Maintenance
REMOTE
1
CAM DATA (H)
Data from the camera to the remote control (H)
2
CAM DATA (C)
Data from the camera to the remote control (C)
3
CAM CONT (H)
Control signals from the remote control to the camera (H)
4
CAM CONT (C)
Control signals from the remote control to the camera (C)
5
RC-ON
Identification signals of the remote control
Low: ON
6
RC VIDEO OUT
Video signals output to the remote control
7
RC VIDEO GND
GND of the video signals to the remote control
8
NC
Not used
9
UNREG 12V
DC 12 V power supply (AJ-RC10G: Max. 0.75 A)
10 GND
GND
VF
1
UNREG-12V
DC 12 V power supply (AJ-HVF21KG: About 0.35 A)
2
UNREG-12V
DC 12 V power supply
3
A9.0V
DC 9 V power supply (not used)
4
VF-PB-GND
GND for the viewfinder P
B
signals
5
VF-PR-GND
GND for the viewfinder P
R
signals
6
VF-Y
Viewfinder Y signals output
7
VF-Y-GND
GND for the viewfinder Y signals
8
VF-CLK
Serial data clock pulse signals
9
VF-WR
Pulse signals for reading serial-parallel conversion data
10 VF-DATA
Serial data signals for serial-parallel conversion
11 UNREG-GND
GND
12 ZEBRA-SW
ON/OFF of the zebra signals
13 PEAKING
Control of the peaking (not used)
14 SPARE
Standby (not used)
15 VF-PR
Viewfinder P
R
signal output
16 VF-PB
Viewfinder P
B
signal output
17 MARKER-SW
ON/OFF of the marker (not used)
18 FRONT-VR
FRONT AUDIO LEVEL adjustment (not used)
19 VR-GND
GND for the FRONT AUDIO LEVEL (not used)
20 UNREG-GND
GND
Caution
Total amount of current from the respective connectors for DC OUT, REMOTE,
VF, and LENS should not exceed 2.5 A.
1
2
4
5
6
7
8
9
10
3
Panasonic part number K1AY110JA001
Maker part number
HR10A-10R-10SC(71)
(Hirose Denki)
Connector at the cable side
Maker part number
HR10A-10P-10P(73)
(Hirose Denki)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
1
8
19
20
Panasonic part number K1AB120H0001
Maker part number
HR12-14RA-20SC
(Hirose Denki)
AJ-HPX3100G(VQT3A79)_E.book 150 ページ 2010年9月17日 金曜日 午後9時21分