If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the WARNING
lamp, lamps inside the viewfinder and a warning tone.
Note
The WARNING lamp has the highest priority, followed by the tally lamp, and then the warning tone. When multiple errors occur
simultaneously a higher priority indication will be triggered. The [9. Low Wireless Signal Reception], however, may not be
indicated, depending on the menu setting.
Warning System
Warning Description Tables
1. System Errors
Display window
indication
The error code lights up.
WARNING lamp
Blinks 4 times per second.
Tally lamp
Blinks 4 times per second.
Viewfinder
The SYSTEM ERROR indication and the error
code light up.
Warning tone
Beeps continuously.
Warning
description
An error in the reference signal or the
communication.
Recording/
playback
operation
The operation stops.
Countermeasures
Please confirm [Error Codes] (page 155) and
consult your distributor.
3. Battery Empty
Display window
indication
All 7 bar indicators for battery remaining
capacity start blinking.
WARNING lamp
Lights up.
Tally lamp
Blinks once per second.
Viewfinder
The BATT LED lights up.
Warning tone
Beeps continuously.
Warning
description
The battery has run out.
Recording/
playback
operation
The operation stops.
Countermeasures
Replace the battery.
2. Card removal error
Display window
indication
Error code E-30 blinks.
WARNING lamp
Blinks 4 times per second.
Tally lamp
Blinks 4 times per second.
Viewfinder
The “TURN POWER OFF” indicator lights up.
Warning tone
Continues to beep.
Warning
description
The P2 card being accessed has been
removed, resulting in an error in the internal
memory of the camera-recorder.
Recording/
playback
operation
Cannot be performed.
Countermeasures
Turn off the power to the camera-recorder. If
there is an error in a clip on the removed P2
card, repair the clip.
4. P2 Card Fully Recorded
Display window
indication
All 7 bar indicators for remaining MEDIA
capacity start blinking.
WARNING lamp
This lamp will illuminate continuously until an
operation is made after recording.
Tally lamp
This lamp will flash 4 times every second until
an operation is made after recording.
Viewfinder
The END indicator blinks.
Warning tone
This tone will sound continuously until an
operation is made after recording.
Warning
description
The P2 cards are recorded to maximum
capacity.
Recording/
playback
operation
The recording stops.
Countermeasures
Delete the clips in the P2 card or insert a new
P2 card.