MAIN OPERATION
BATTERY/P2CARD
Items/
Data Saved
Adjustable
Range
Remarks
BATTERY
SELECT
HYTRON140
DIONIC90
DIONIC160
ENDURA10
PAG L95
TYPE A
TYPE B
TYPE C
Select the battery to use. Battery-
remaining detection matched to the
battery is performed when HYTRON 140,
DIONIC 90, or DIONIC 160 from Anton/
Bauer, ENDURA 10 (E-10) from IDX, or
PAG L95 from PAG is selected.
Select TYPE A, TYPE B, or TYPE C for
batteries other than those mentioned
above. At this time, set FULL (full
voltage), NEAR END (near end warning
voltage), and END (end voltage) for the
selected battery type in the [BATTERY
SETTING] (page 188).
The initial values for TYPE A are set
matching the IDX ENDURA ELITE-S, and
TYPE B is set matching the Anton/Bauer
HYTRON 140.
– C U F –
EXT DC IN
SELECT
AC_ADPT
HYTRON140
DIONIC90
DIONIC160
ENDURA10
PAG L95
TYPE A
TYPE B
TYPE C
Set the remaining capacity detection type
when a battery is connected to the DC IN
connector. Remaining capacity detection
is also performed according to the
selected battery type.
Selection of battery types is similar to the
above mentioned BATTERY SELECT
menu option.
Analog voltage is displayed on the
viewfinder screen.
– C U F –
BATT NEAR
END ALARM
ON
OFF
Select whether or not to set the alarm to
beep for BATT NEAR END ALARM.
– C U F –
BATT NEAR
END CANCEL
ON
OFF
If set to ON, the warning tone and
indication can be canceled by pulling the
MARKER SEL, MODE CHK/MENU
CANCEL switch when BATT NEAR END
ALARM is triggered.
– C U F –
BATT END
ALARM
ON
OFF
Select whether or not to set the alarm to
beep for BATT END ALARM.
– C U F –
BATT REMAIN
FULL
70%
100%
Set the display of the remaining battery
level indicator bar in the display window
when a battery with this function is used.
70%:
Indicate FULL at 70% capacity.
100%:
Indicate FULL at 100% capacity.
– C U F –
Items/
Data Saved
Adjustable
Range
Remarks
CARD NEAR
END ALARM
ON
OFF
Select whether or not to set the alarm to
beep for P2 CARD NEAR END ALARM.
– C U F –
CARD NEAR
END TIME
2min
3min
Set the remaining time to indicate the P2
CARD NEAR END TIME alarm.
– C U F –
CARD END
ALARM
ON
OFF
Select whether or not to set the alarm to
beep for P2 CARD END ALARM.
– C U F –
CARD
REMAIN/
3min/
5min/
Set the length of time for one segment
(
) of the P2 card’s remaining capacity
indicator bars.
3min/
:
One segment represents 3
minutes.
5min/
:
One segment represents 5
minutes.
– C U F –