134
Maintenance and Inspections : Warning System
5. P2 Card Fully Recorded
Display window
indication
All 7 bar indicators for remaining MEDIA
capacity start blinking.
WARNING lamp
This lamp will illuminate continuously until an
operation is made after recording.
Tally lamp
This lamp will flash 4 times every second
until an operation is made after recording.
Viewfinder
The END indicator blinks.
Warning tone
This tone will sound continuously until an
operation is made after recording.
Warning
description
The P2 cards are recorded to maximum
capacity.
Recording/
playback
operation
The recording stops.
Countermeasures
Delete the clips in the P2 card or insert a
new P2 card.
7. Low Wireless Signal Reception
Display window
indication
No display.
WARNING lamp
Blinks 4 times per second. (During pause
and recording)
Tally lamp
Blinks 4 times per second while recording
continues.
Viewfinder
The WIRELESS RF indicator lights up while
recording continues.
Warning tone
Beeps 4 times per second while recording
continues.
Warning
description
This error indicates poor wireless audio
reception conditions.
Recording/
playback
operation
Continues to operate without receiving the
wireless microphone signal.
Countermeasures
Check the microphone power supply and the
reception status of the wireless receiver.
6. Recording Error
Display window
indication
“00:00:00:11” appears in the time code
display field. Even after recording is stopped,
this display continues to blink until the next
operation is performed.
WARNING lamp
Blinks 4 times per second while recording
continues.
Tally lamp
Blinks 4 times per second while recording
continues.
Viewfinder
The REC WARNING indicator lights up.
Warning tone
Beeps 4 times per second while recording
continues.
Warning
description
This indicates a failure either in the P2 card
recording or the recording circuit.
Recording/
playback
operation
Recording stops.
Countermeasures
Restart recording. Or, turn the power OFF
and turn it ON again, before starting
recording.
8. 1394 Error
Display window
indication
The 1394 E-
¢¢
indicator in the display
window blinks. For more information, see
[1394 Error Codes] (page 136).
WARNING lamp
Blinks 4 times per second while the
WARNING lamp recording is continuing.
Tally lamp
Blinks 4 times per second while the TALLY
LAMP recording is continuing.
Viewfinder
In the case of Error Code 92, “1394 INITIAL
ERROR” indicator lights up (during pause
and recording)
For Error Codes other than Error Code 92, or
if REC SIGNAL is set to “1394”, no error is
displayed in the viewfinder.
Warning tone
Beeps 4 times per second while ALARM
recording is continuing.
Warning
description
This indicates a failure of the DVCPRO/DV
connector.
Recording/
playback
operation
The operation continues, but input signals to
the DVCPRO/DV connector are abnormal.
For more information, see [1394 Error
Codes] (page 136).
Countermeasures
Check the connection between the
IEEE1394 cable and the DVCPRO/DV
connector, settings of any external device
and menus, and the turn on the power again.
If the warning indication is still illuminated,
confirm the “1394 Error Codes” (page 136),
and consult your distributor.
AJ-HPX2100E(English).book 134 ページ 2006年11月27日 月曜日 午後4時34分