7-35
Axis [Group]
The axis numbers and group names to be monitored.
Synchronous group
The group name and the master/slave axis type fot the synchronous
operation.
Synchronous mode
The operation mode for the synchronous operation.
Synchronous
condition
Monitor the synchronous/asynchronous condition in the synchronous
operation.
For the synchronous operation in the operation mode A, clicking
[Synchronous change] changes the condition.
Current value
Monitor the feedback value for every axis after unit conversion.
Clicking [Current value update] displays the dialog for inputting the value,
and it enables to change the current value.
Unit
Indicate the unit of positions for the axes specified in the parameter settings
each from the positioning unit.
Deviation (Pulse)
Indicate the deviation when activating the moving amount automatic check
function.
Active table number
Indicate the table number during the operation or when it completes.
Starting table number
The starting table number for the positioning control.
Click [Change] to change the starting table number.
Operate/Stop
Execute the operation to start/stop the home return.
・
Click [Operate] to execute the positioning operation. The button name
changes to [Stop].
・
Click [Stop] to execute the deceleration stop operation. The button name
changes to [Operate].
State of axis
The operating states of axes or error and warning occurrences.
Error code
The latest error code when an error occurred.
Error clear
Clear the error by clicking this button, when an error occurred.
Warning code
Indicate the latest warning code when a warning occurs.
Warning clear
Clear the warning by clicking this button, when a warning occurred.
Speed rate
The target speed of the home return specified in the parameter settings for
each axis is regarded as 100%, and the operation is executed in the
specified speed rate.
Clicking [Speed rate] shows the dialog for inputting the value.
Note:
If a recoverable error occurred in the positioning unit, click [Error Clear] to clear the error.
If a warning occurred in the positioning unit, click [Warning Clear] to clear the warning.
2. Click [Change] in the starting table number field to specify the starting table number.
Specify the starting table number and click [Operate] to start the positioning opration.
Note:
In the positioning unit, the positioning operation for the interpolation group is performed to request the
start and stop for the smallest number of axes in the group.
In the tool operation, the positioning operation for the interpolation group is performed by clicking
[Operate] for any axes. However, due to the above specifications, a warning message is shown when
any [Operate] button other than the one for the smallest axis number is clicked.
3. Click [Close] to close the dialog.
Note:
This dialog cannot be closed during the positioning operation.
Содержание AFP243710
Страница 16: ...xiv ...
Страница 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Страница 21: ...Chapter 2 Parts and Functions ...
Страница 24: ...2 4 ...
Страница 25: ...Chapter 3 Wiring ...
Страница 39: ...Chapter 4 Power On Off and Items to Check ...
Страница 44: ...4 6 ...
Страница 45: ...Chapter 5 Preparation For Operation ...
Страница 53: ...5 9 ...
Страница 55: ...Chapter 6 I O Allocation ...
Страница 63: ...Chapter 7 Setting Tool Configurator PM ...
Страница 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Страница 102: ...7 40 ...
Страница 103: ...Chapter 8 Automatic Operation Position Control ...
Страница 115: ...8 13 ...
Страница 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Страница 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Страница 139: ...Chapter 9 Manual Operation JOG Operation ...
Страница 144: ...9 6 ...
Страница 145: ...Chapter 10 Manual Operation Home Return ...
Страница 151: ...Chapter 11 Manual Operation Pulser Operation ...
Страница 155: ...Chapter 12 Stop Functions ...
Страница 158: ...12 4 ...
Страница 159: ...Chapter 13 Supplementary Functions ...
Страница 171: ...Chapter 14 Precautions During Programming ...
Страница 175: ...Chapter 15 Errors and Warnings ...
Страница 186: ...15 12 ...
Страница 187: ...Chapter 16 Troubleshooting ...
Страница 190: ...16 4 ...
Страница 191: ...Chapter 17 Specifications ...
Страница 241: ...Chapter 18 Dimensions ...
Страница 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Страница 243: ...Chapter 19 Sample Programs ...
Страница 247: ...19 5 ...
Страница 250: ...19 8 ...
Страница 251: ...Chapter 20 Driver Wiring ...
Страница 261: ......