17-6
Contact
allocation
Target
axis
Name
Descriptions
W
X
2
X20
1 axis
Operation done
Turns on when the operation command for the corresponding axis
completed and the position error became in the specified completion width.
For P point control and C point control of the automatic operation, turns on
when the operation for all the tables completed.
After this contact turned on, the on-state continues until the next control
activates.
X21
2 axis
X22
3 axis
X23
4 axis
X24
-
-
-
X25
-
-
-
X26
-
-
-
X27
-
-
-
X28
1 axis
Home return done
Turns on when the home return operation for the corresponding axis
completed. After this contact turned on, the on-state continues until the next
control activates.
X29
2 axis
X2A
3 axis
X2B
4 axis
X2C
-
-
-
X2D
-
-
-
X2E
-
-
-
X2F
-
-
-
W
X
3
X30
1 axis
Home
The contact to monitor the external home input signal for the corresponding
axis.
X31
2 axis
X32
3 axis
X33
4 axis
X34
-
-
-
X35
-
-
-
X36
-
-
-
X37
-
-
-
X38
1 axis
Near home
The contact to monitor the external near home input signal for the
corresponding axis.
X39
2 axis
X3A
3 axis
X3B
4 axis
X3C
-
-
-
X3D
-
-
-
X3E
-
-
-
X3F
-
-
-
W
X
4
X40
-
-
-
X41
-
-
-
X42
-
-
-
X43
-
-
-
X44
-
-
-
X45
-
-
-
X46
-
-
-
X47
-
-
-
X48
1 axis
Auxiliary contact
Turns on when the corresponding positioning table of the corresponding
axis was executed.
Use Configurator PM or directly write in the shared memory for setting to
able/disable the auxiliary contact.
X49
2 axis
X4A
3 axis
X4B
4 axis
X4C
-
-
-
X4D
-
-
-
X4E
-
-
-
X4F
-
-
-
Содержание AFP243710
Страница 16: ...xiv ...
Страница 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Страница 21: ...Chapter 2 Parts and Functions ...
Страница 24: ...2 4 ...
Страница 25: ...Chapter 3 Wiring ...
Страница 39: ...Chapter 4 Power On Off and Items to Check ...
Страница 44: ...4 6 ...
Страница 45: ...Chapter 5 Preparation For Operation ...
Страница 53: ...5 9 ...
Страница 55: ...Chapter 6 I O Allocation ...
Страница 63: ...Chapter 7 Setting Tool Configurator PM ...
Страница 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Страница 102: ...7 40 ...
Страница 103: ...Chapter 8 Automatic Operation Position Control ...
Страница 115: ...8 13 ...
Страница 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Страница 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Страница 139: ...Chapter 9 Manual Operation JOG Operation ...
Страница 144: ...9 6 ...
Страница 145: ...Chapter 10 Manual Operation Home Return ...
Страница 151: ...Chapter 11 Manual Operation Pulser Operation ...
Страница 155: ...Chapter 12 Stop Functions ...
Страница 158: ...12 4 ...
Страница 159: ...Chapter 13 Supplementary Functions ...
Страница 171: ...Chapter 14 Precautions During Programming ...
Страница 175: ...Chapter 15 Errors and Warnings ...
Страница 186: ...15 12 ...
Страница 187: ...Chapter 16 Troubleshooting ...
Страница 190: ...16 4 ...
Страница 191: ...Chapter 17 Specifications ...
Страница 241: ...Chapter 18 Dimensions ...
Страница 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Страница 243: ...Chapter 19 Sample Programs ...
Страница 247: ...19 5 ...
Страница 250: ...19 8 ...
Страница 251: ...Chapter 20 Driver Wiring ...
Страница 261: ......