xii
Auxiliary output code, auxiliary output contact
They are used to check the operation of a position control.
The auxiliary output code is a 16-bit code that can be specified for each positioning table, and enables to
monitor which positioning table is being executed.
The exeuction fo the position control can be confirmed by turning an exclusive auxiliary output contact on
for a constant time.
Software limit
Limits can be set for the absolute coordinate managed within the positioning unit RTEX. When
exceeding the setting range of the software limit, an error occurs, and the system decelerates and stops.
The decelration time can be set individually.
Linear interpolation
This is the interpolation control that controls positions as the locas of the operations of the 2-axis motor
with the grouped X axis and Y axis or 3-axis motor with the grouped X axis, Y axis and Z axis becomes a
straight line. There are two setting methods, which are a composition speed specification and long axis
speed specification.
Circular interpolation
This is the inerpolation control that controls positions as the locas of the operation of the 2-axis motor
with the grouped X axis and Y axis becomes a circular arc. Therea re tow setting methods, which are a
center point specification and pass point specification.
Spiral interpolation
This is the interpolation control that controls positions as the loca of the operation of the 3-axis motor
with the grouped X axis, Y axis and Z axis becomes a spiral. Arbitrary 2 axes describe an arc, and the
remaining one axis moves to achieve a spiral There are two setting methods, which are a center point
specification and pass point specification.
Edge type
This is one of the methods to detect the request signals allocated to this unit. It executes each requested
process by detecting a trigger that is the leading edge when the request signal turns on.
Therefore, the next request cannot be accepted until the request signal turns off.
Level type
This si one of the methods to detect the request signals allocated to this unit. It executes each requested
process by detecting a trigger that the request signal is on, and continues the requested process while
the request signal is on.
Содержание AFP243710
Страница 16: ...xiv ...
Страница 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Страница 21: ...Chapter 2 Parts and Functions ...
Страница 24: ...2 4 ...
Страница 25: ...Chapter 3 Wiring ...
Страница 39: ...Chapter 4 Power On Off and Items to Check ...
Страница 44: ...4 6 ...
Страница 45: ...Chapter 5 Preparation For Operation ...
Страница 53: ...5 9 ...
Страница 55: ...Chapter 6 I O Allocation ...
Страница 63: ...Chapter 7 Setting Tool Configurator PM ...
Страница 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Страница 102: ...7 40 ...
Страница 103: ...Chapter 8 Automatic Operation Position Control ...
Страница 115: ...8 13 ...
Страница 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Страница 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Страница 139: ...Chapter 9 Manual Operation JOG Operation ...
Страница 144: ...9 6 ...
Страница 145: ...Chapter 10 Manual Operation Home Return ...
Страница 151: ...Chapter 11 Manual Operation Pulser Operation ...
Страница 155: ...Chapter 12 Stop Functions ...
Страница 158: ...12 4 ...
Страница 159: ...Chapter 13 Supplementary Functions ...
Страница 171: ...Chapter 14 Precautions During Programming ...
Страница 175: ...Chapter 15 Errors and Warnings ...
Страница 186: ...15 12 ...
Страница 187: ...Chapter 16 Troubleshooting ...
Страница 190: ...16 4 ...
Страница 191: ...Chapter 17 Specifications ...
Страница 241: ...Chapter 18 Dimensions ...
Страница 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Страница 243: ...Chapter 19 Sample Programs ...
Страница 247: ...19 5 ...
Страница 250: ...19 8 ...
Страница 251: ...Chapter 20 Driver Wiring ...
Страница 261: ......