11-2
11.1 Setting and Operation of Pulser Operation
Types of pulse operation
The pulser operation is a function to output pulses in the manual operation using the pulser connected to
the positioning unit.
The following operation methods can be used.
Operation method
Operation
Standard operation
Obtains the number of pulses of the pulser in increment of 1 ms, and operates.
The content of the input from the pulser are reflected in the actual operation as
it is.
Speed limit
(keep pulse)
Operates keeping the maximum speed, once the speed of the pulser input
exceeds the specified maximum speed.
The number of pulses that has been input with the pulser is kept. As the pulse
that could not be output is kept, the pulse may be ouput even without input
from the pulser.
Speed unit is "Set unit X1000/s".
Speed limit (cutoff)
Operates keeping the maximum speed, once the speed of the pulser input
exceeds the specified maximum speed The pulse that could not be output is
cut off, and the pulse output is processed simultaneously with the operation of
the pulser.
Speed unit is "Set unit X1000/s".
The example below is the case of the positioning unit installed in the slot 0. The unit is set to pulse.
Содержание AFP243710
Страница 16: ...xiv ...
Страница 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Страница 21: ...Chapter 2 Parts and Functions ...
Страница 24: ...2 4 ...
Страница 25: ...Chapter 3 Wiring ...
Страница 39: ...Chapter 4 Power On Off and Items to Check ...
Страница 44: ...4 6 ...
Страница 45: ...Chapter 5 Preparation For Operation ...
Страница 53: ...5 9 ...
Страница 55: ...Chapter 6 I O Allocation ...
Страница 63: ...Chapter 7 Setting Tool Configurator PM ...
Страница 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Страница 102: ...7 40 ...
Страница 103: ...Chapter 8 Automatic Operation Position Control ...
Страница 115: ...8 13 ...
Страница 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Страница 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Страница 139: ...Chapter 9 Manual Operation JOG Operation ...
Страница 144: ...9 6 ...
Страница 145: ...Chapter 10 Manual Operation Home Return ...
Страница 151: ...Chapter 11 Manual Operation Pulser Operation ...
Страница 155: ...Chapter 12 Stop Functions ...
Страница 158: ...12 4 ...
Страница 159: ...Chapter 13 Supplementary Functions ...
Страница 171: ...Chapter 14 Precautions During Programming ...
Страница 175: ...Chapter 15 Errors and Warnings ...
Страница 186: ...15 12 ...
Страница 187: ...Chapter 16 Troubleshooting ...
Страница 190: ...16 4 ...
Страница 191: ...Chapter 17 Specifications ...
Страница 241: ...Chapter 18 Dimensions ...
Страница 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Страница 243: ...Chapter 19 Sample Programs ...
Страница 247: ...19 5 ...
Страница 250: ...19 8 ...
Страница 251: ...Chapter 20 Driver Wiring ...
Страница 261: ......