5-10
5.6 Procedure 6: Settings of Parameters and Positioning
Data
Procedure 1
Set the parameters and positioning data in accordance with the actual operation.
Points to check
The parameters and positioning data is stored in the shared memory of the positioning unit. Although
there are two methods to store the data in the shared memory, it is recommended to set the parameters
that are not changed so often using the Configurator PM.
- Use the Configurator PM
- Use the program to write into the shared memory
Procedure 2.1
When using the Configurator PM
Boot the Configurator PM, and select
“Set axis”
“Parameter settings” on the menu to set the various
parameters. Also, create the table for the positioning table on the positioning data editing screen. After
setting the parameters and data, download them to the positioning unit.
Points to check
After the parameters and posiioning data was downloaded, the display to select whether to write them
into the FROM (flash memory) or not is shown. When they are written into the flash memory, the
parameters and positioning data in the flash memory will be automatically reflected to the shared
memory when the power supply of the PLC turns on. When they are not written into the flash memory,
the parameters and positioning data finaly stored in the flash memory will be reflected when the power
supply of the PLC turns on.
Procedure 2.2
When using the ladder program to write into the shared memory
Use the F151 instruction to write various parameters and positioning data into the shared memory.
Reference:
For the information on the storage addresses of various parameters and postioning data,
<17.6 Details of Each Axis Setting Area in Shared Memory>
For the information on writing positioning data using ladder programs,
<14.1.3. How to Use Standard Area and Extended Area of Positioning Data>
Содержание AFP243710
Страница 16: ...xiv ...
Страница 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Страница 21: ...Chapter 2 Parts and Functions ...
Страница 24: ...2 4 ...
Страница 25: ...Chapter 3 Wiring ...
Страница 39: ...Chapter 4 Power On Off and Items to Check ...
Страница 44: ...4 6 ...
Страница 45: ...Chapter 5 Preparation For Operation ...
Страница 53: ...5 9 ...
Страница 55: ...Chapter 6 I O Allocation ...
Страница 63: ...Chapter 7 Setting Tool Configurator PM ...
Страница 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Страница 102: ...7 40 ...
Страница 103: ...Chapter 8 Automatic Operation Position Control ...
Страница 115: ...8 13 ...
Страница 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Страница 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Страница 139: ...Chapter 9 Manual Operation JOG Operation ...
Страница 144: ...9 6 ...
Страница 145: ...Chapter 10 Manual Operation Home Return ...
Страница 151: ...Chapter 11 Manual Operation Pulser Operation ...
Страница 155: ...Chapter 12 Stop Functions ...
Страница 158: ...12 4 ...
Страница 159: ...Chapter 13 Supplementary Functions ...
Страница 171: ...Chapter 14 Precautions During Programming ...
Страница 175: ...Chapter 15 Errors and Warnings ...
Страница 186: ...15 12 ...
Страница 187: ...Chapter 16 Troubleshooting ...
Страница 190: ...16 4 ...
Страница 191: ...Chapter 17 Specifications ...
Страница 241: ...Chapter 18 Dimensions ...
Страница 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Страница 243: ...Chapter 19 Sample Programs ...
Страница 247: ...19 5 ...
Страница 250: ...19 8 ...
Страница 251: ...Chapter 20 Driver Wiring ...
Страница 261: ......