ix
J point control (JOG positioning control)
This refers to control which passes through a
“JOG Operation Point”, and is called “J point control” in this
manual. Executing the J point control performs the speed control until a
“J pont positioning start contact”
turns on.
Acceleration time/deceleration time
For the E point control or C point contro, the acceleration time is the time during which the speed
changes from the startup speed of a motor to the target speed. The deceleration time is the time during
which the speed changes from the target speed to the stop. For the P point control, the acceleraiton time
is the time during which the speed accelerates form the current speed to the next target speed, and the
deceleration time is the time during which the speed decelerates from the current speed to the next
target speed.
CW, CCW
Generally, these indicate the direction in which the motor is rotating, with CW referring to clockwise
rotation and CCW to counterclockwise rotation.
CW/CCW output method (2-pulse output method)
This is a method in which control is carried out using two pulses, a forward rotation pulse and a reverse
rotation pulse. With the FP2 positioning unit, this is specified using the control codes of the shared
memory according to the driver specifications.
Pulse/Sign output method (1-pulse output method)
This is a method in which control is carried out using one pulse to specify the speed and ON/OFF signals
to specify the direction of rotation. With the FP2 positioning unit, this is specified using the control codes
of the shared memory according to the driver specifications.
Absolute method (absolute value control method)
This is a control method in which the target position is specified as an absolute position from the home
position. This is specified on the positioning data editing screen of the Configurator PM.
Содержание AFP243710
Страница 16: ...xiv ...
Страница 17: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Страница 21: ...Chapter 2 Parts and Functions ...
Страница 24: ...2 4 ...
Страница 25: ...Chapter 3 Wiring ...
Страница 39: ...Chapter 4 Power On Off and Items to Check ...
Страница 44: ...4 6 ...
Страница 45: ...Chapter 5 Preparation For Operation ...
Страница 53: ...5 9 ...
Страница 55: ...Chapter 6 I O Allocation ...
Страница 63: ...Chapter 7 Setting Tool Configurator PM ...
Страница 87: ...7 25 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Страница 102: ...7 40 ...
Страница 103: ...Chapter 8 Automatic Operation Position Control ...
Страница 115: ...8 13 ...
Страница 116: ...8 14 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Страница 129: ...8 27 Reference Chapter 10 Manual Operation Home Return ...
Страница 139: ...Chapter 9 Manual Operation JOG Operation ...
Страница 144: ...9 6 ...
Страница 145: ...Chapter 10 Manual Operation Home Return ...
Страница 151: ...Chapter 11 Manual Operation Pulser Operation ...
Страница 155: ...Chapter 12 Stop Functions ...
Страница 158: ...12 4 ...
Страница 159: ...Chapter 13 Supplementary Functions ...
Страница 171: ...Chapter 14 Precautions During Programming ...
Страница 175: ...Chapter 15 Errors and Warnings ...
Страница 186: ...15 12 ...
Страница 187: ...Chapter 16 Troubleshooting ...
Страница 190: ...16 4 ...
Страница 191: ...Chapter 17 Specifications ...
Страница 241: ...Chapter 18 Dimensions ...
Страница 242: ...18 2 18 1 FP2 Positioning Unit Interpolation Type 2 axis type Unit mm 4 axis type Unit mm ...
Страница 243: ...Chapter 19 Sample Programs ...
Страница 247: ...19 5 ...
Страница 250: ...19 8 ...
Страница 251: ...Chapter 20 Driver Wiring ...
Страница 261: ......