Configuration - Autodos M1 pH
Line
Text
Setting
Explanation
-01
FLo
Selection of flow switch and alarm for low flow.
oFF
No flow switch. Flow alarm OFF.
Son
Flow switch that closes with flow. Flow alarm ON.
Pof
Turbine flow meter. Flow alarm OFF.
Pon*
Turbine flow meter. Flow alarm ON.
-02
PHd
Selection of pH-adjusted dosing.
ACi*
Doses acid (doses when actual value > set value).
bAS
Doses alkali (doses when actual value < set value).
-03
PHc
Selection of pH calibration point 2.
Calibration point 1 = pH 7.00
PH9*
Calibration point 2 = pH 9.00
PH4
Calibration point 2 = pH 4.00
-04
PC
Setting of access from PC.
No*
No access (display only).
rES
Alarm reset only.
Prg
Fully programmable.
-05
Sio
001-255 (001*)
Selection of Modbus ID number
-06
FLd
000-030 (000*) [minutes]
Flow alarm delay time.
-07
rEL
000-030 (000*) [minutes]
Alarm relay delay time.
-08
Sby
The Sby input blocks all dosing plus the alarm relay.
rEL*
Activates the alarm.
non
Does not activate the alarm.
* Factory default!
Electrode-specific configuration – general
To access configuration mode, see page 19.
NOTE! Before starting up check the setting for electrode-specific configuration; row -01 for each channel (redox / chlorine / pH):
This must correspond to the electrical connection of the dosing equipment (On/Off or Frequency dosing) for each connection
example. If that does not conform it will cause damage to the circuit board.
NOTE! Dosing should not be charged with 230VAC when selecting the type of dosing Frequency control.
The following button combinations are used to enter the different configuration modes:
All M1, M2 and M3 models - Free chlorine, combined chlorine, pH
Basic functions:
Function
[11] +
Reset
[15]
Configuration for electrode 1:
Set value
[13] +
Select function
[1]
Configuration for electrode 2:
Set value
[13] +
Select function
[4]
Configuration for electrode 3:
Set value
[13] +
Select function
[7]
M3 - Free chlorine, redox, pH
Basic functions:
Set acid
[11] +
Reset
[15]
Configuration for electrode 1:
Set alk/Chl
[13] +
Select function
[1]
Configuration for electrode 3 (acid):
Set acid
[11] +
Select function
[7]
Configuration for electrode 3 (alkali):
Set alk/Chl
[13] +
Select function
[7]
Flashing LEDs confirm which configuration mode you accessed when the buttons are released: Active configuration is indicated
by the “
Active
” LED flashing. If any of the electrode-specific configuration modes are active, the LEDs “
Off
” and “
Auto
” flash for
the relevant electrode.