Pacific Energy Limited Lifetime Warranty Wood Products

 

Pacific Energy extends the following warranty coverage to the original registered purchaser of the product: 

LTD Lifetime Coverage (10 years) 

Limited lifetime coverage is extended to the following components (parts only) porcelain finish, glass (glass for 
thermal  breakage only, not impact), plating, firebox and baffle. 

3 Year Comprehensive

 

Pacific Energy will replace or repair any part found to be defective (parts and labor) for three years from the 
date of purchase. 

This coverage includes electrical components (blowers, speed controls and thermal switches). 

Conditions: 

Your stove has been designed to perform in the harshest climates in North America. You can be confi-

dent that  under normal use your stove will be trouble free for many years.  If your stove is prematurely 
deteriorating this is  a significant indicator of improper usage, for example; excessive draft, heating to 
large an area, contaminated fuel - such as high sodium content or plastics and chemicals. Please be 
aware, these conditions may be reasons to  void your warranty.

 

For wood products 

- All installations must be installed according to all applicable local and national codes. It is the responsibility 

of the installer to ensure the unit is operating correctly at installation. 

Any part that shows in our judgment evidence of defect shall be repaired, replaced or refunded at Pacific 

Energy’s option. The defective part may be required to be returned to Pacific Energy or an accredited agent, 
transportation prepaid. 

Porcelain 

is warranted for gloss retention. Certain colors may darken when heated and return to the original 

shade when cool. 

Glass 

is warranted against thermal breakage. 

Plating 

is warranted against tarnishing. Gold plating may attain a deeper color with use. 

Exclusions

 

Limited Lifetime coverage - Lifetime coverage is limited to the repair, replacement or refund of the indicated 
parts only.  

Labor charges are not covered under the lifetime warranty. 

The following items are not included in the Liftetime Warranty: firebox rails and heat shields.

The following parts are not warranted: firebrick, gaskets and ceramic fiber blankets. 

 Waranty Information 

36

100001385_071118-40

FP25

Содержание FP25

Страница 1: ...cialsabout restrictions and installation inspection requirements in your area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER PLEASE SAVE THESE INSTRUCTIONS MODEL FP25 FP25AR ZERO CLEARA...

Страница 2: ...14 Blower Replacement 14 Fireplace Installation 15 Locating your Fireplace 15 Mobile Home Installation notes 15 Crate Removal 15 Dimensions 16 Fireplace Clearances and Dimensions 16 Minimum Framing D...

Страница 3: ...l become proficient in operating your heater and will obtain the performance for which it was designed EPA Certified Emissions 3 5 grams per hour LHV Tested Efficiency 1 72 6 HHV Tested Efficiency 2 6...

Страница 4: ...is area is at the front of the firebox 4 If glass becomes darkened through slow burning or poor wood it can be cleaned with fireplace glass cleaner when the fireplace is cold Never scrape with an obje...

Страница 5: ...ation clearances or within the space required for fuel loading and ash removal Keep the area around the heater clean and free of loose combustibles furniture newspa pers etc 9 Instruct all members of...

Страница 6: ...ned down and cooled remove excess ashes Leave an ash bed approximately 1 25 mm deep on the firebox bottom to help maintain a hot charcoal bed Disposal of Ashes Ashes should be placed in a metal contai...

Страница 7: ...x just in front of the baffle supply tube Remove the bricks to expose the access panel then remove the 2 screws holding the access panel 2 Use a vacuum to suck out any debris 3 Replace the access pane...

Страница 8: ...isture laden smoke cools the chimney compounding the problem by offering the smoke the ideal place to condense In summary a certain amount of creosote is inevitable and must be lived with Regular insp...

Страница 9: ...ing condition can be hazardous and may void the manufacturer s warranty Wood Selection This heater is designed to burn natural wood only Higher efficiency and lower emissions generally result when bur...

Страница 10: ...risscross with several pieces of dry kindling Add a few small pieces of dry wood on top 3 Ignite the paper and leave the door ajar approximately 1 2 13mm 1 25mm until the wood kindling is fully engulf...

Страница 11: ...modification of the combustion air control assembly is permitted Any tampering will void warranty and could be very hazardous WARNING Do not use grates or andirons to elevate the fuel Burn directly on...

Страница 12: ...em NA The ash dump handle is located under the ash lip on the left hand side behind the lower grill To operate ash dump remove the lower grill pull handle out 1 2 13mm and turn clockwise This will unl...

Страница 13: ...emoval steps in the reverse order Ensure that the two side pieces of insulation are set tight against the baffle If the insulation is damaged during removal it should be replaced Secondary Air Box Cle...

Страница 14: ...front by lifting and pulling away from the unit Remove the four screws securing the back surround to the brackets and set the surround aside carefully to avoid damage 2 With a 3 8 wrench loosen the t...

Страница 15: ...actor in the chimney performance Therefore the chimney out let position is important when locating the fireplace We recommend whenever possible that the chimney should Penetrate the highest part of th...

Страница 16: ...7 2 13m Minimum distance of adjacent wall to side of fireplace door 22 560mm Minimum distance to Max 4 deep side facing from fireplace door opening 11 1 2 292mm Minimum width of floor protection from...

Страница 17: ...e chase is required for heat management Do Not build a recess shelves or cupboards in the area above this fireplace Do not build anything inside this Minimum chase area Do Not insulate the front porti...

Страница 18: ...e bottom stud 2 and then attach the top stud 2 to the center supports 3 Installing the unit into the chase Push the Fireplace into place Casing must be flush with the framing in the front and secure i...

Страница 19: ...the chimney manufacturer s instal lation requirements Consult your chimney supplier for installation advice 1 After locating the desired location and framing in the fireplace use a plumb bob to line...

Страница 20: ...supported after the first 20 6 1m in length 1 NOTE Install the vertical chimney section s then the first elbow and turn it in the required direction 2 Install the necessary chimney lengths to achieve...

Страница 21: ...PA 211 All clearances around the chimney for its entire length must be to code as per the NBC or NFPA 211 The masonry chimney can only be used for this fireplace and no other appliances Make sure the...

Страница 22: ...ide the chase Cover the hole and install a 20GA wire mesh minimum rodent screen and staple nail in place Provide water protection as required by building code Attach 4 102mm venting not supplied betwe...

Страница 23: ...the support base Figure 14 Connect the wiring as shown in the wiring diagram Figure 16 to the wires located in the junction box See Blower Replacement on page 14 All electrical connections should be p...

Страница 24: ...al strip equal to the width of the unit One half of the metal strip must be under the fireplace front and the other half must extend onto the floor and under the hearth extension ember protection as s...

Страница 25: ...at Kit requires 6 Listed Approved B vent gas venting This allows reduced clearances in the wall spaces Follow the clearances and applicible installation guidelines in the vent manufacturers instruc ti...

Страница 26: ...9144 6 BLOWER FAN BRACKET 9146 7 ELECTRICAL CONNECTION COVER 9144 5 8 REMOTE BLOWER BOX WODC 9141 ITEM DESCRIPTION PART NUMBER 12 5 1 4 7 11 13 8 2 6 3 14 9 10 HEAT DUCT Replacement Parts 9 BLOWER 502...

Страница 27: ...length and number of bends To maximize the performance the length and number of bends should be kept to a minimum A 12 305mm from the CEILING or SIDE WALLS B 36 914mm from the FLOOR A A B A A Listed...

Страница 28: ...Place the Backflow Damper into the top of the unit Figure 22 Ensure that the flap in the assembly is free to move Flap should be in the normally closed position with the blower off 4 Attach the Duct...

Страница 29: ...or ridged gas vent pipe vent pipe is not included with this kit between the blower and the fireplace Fasten in place with screws and seal with aluminium foil tape 7 Connect the wiring as per the dire...

Страница 30: ...C22 1 Canadian Electrical Code or in the USA the National Electrical Code ANSI NFPA 70 Latest Edition The Remote Heat Kit blower s electrical rating 120V 60HZ 80 watts For your protection against shoc...

Страница 31: ...m from the top facing stop and 58 1 47m wide centered on the unit The front casing of the fireplace has a built in facing edge stop DO NOT PLACE ANY CEMENT BOARD OR FINISHING MATERIALS INSIDE THIS EDG...

Страница 32: ...COMBUSTIBLES Allowed in this area Figure 29 FP25 Mantle and Pillar Mantel Clearances and Dimensions Minimum distance to the underside of the Mantel max 12 deep from the top of the Heat Exchanger Air...

Страница 33: ...ebricks as well as 5 various cut size bricks With the heater in the upright position install firebricks as follows 1 Install the rear firebricks 4 full size two on each side of the baffle tube Then pl...

Страница 34: ...s wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight 1 Air control is set too high Set control lower 2 Not enoug...

Страница 35: ...rom your nearest Pacific Energy dealer Contact Pacific Energy for the location of the dealer nearest you 3 12 13 14 4 5 6 7 8 16 10 9 2 11 1 15 NE25 DRBK 3a Replacement Parts ITEM DESCRIPTION PART NUM...

Страница 36: ...chemicals Please be aware these conditions may be reasons to void your warranty For wood products All installations must be installed according to all applicable local and national codes It is the re...

Страница 37: ...ial damages of any nature whatsoever which are in excess of the original purchase price of the product Pacific Energy is not responsible for installation operational or environmental conditions beyond...

Страница 38: ...ROUS OPERATION OF THIS AND OTHER APPLIANCES SEE LOCAL BUILDING CODE AND MANUFACTURER S INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING CHIMNEY SYSTEM...

Страница 39: ...39 100001385_071118 40 FP25...

Страница 40: ...Products LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer Web sit...