Baffle Removal
DO NOT OPERATE WITH BAFFLE ASSEMBLY OR INSULATION REMOVED.
WARNING: AFTER YOU REMOVE THE BAFFLE, ALWAYS COVER THE TOP OF THE BAFFLE AIR TUBE
LOCATED IN THE REAR OF THE FIREBOX. THIS PREVENTS DEBRIS FALLING DOWN THE TUBE.
FAILURE TO DO SO WILL RESULT IN POOR OPERATION AND POSSIBLE DAMAGE TO FIREPLACE
COMPONENTS.
Remove retaining pin located just beneath the baffle at the rear inside top of the firebox (Figure 1). Lift baffle
up and pull forward to disconnect from the supply tube. Slide the baflle to one side and then tilt baffle side-
ways to drop down and remove from firebox. To re-install the baffle, perform the removal steps in the reverse
order. Ensure that the two side pieces of insulation are set tight against the baffle. If the insulation is damaged
during removal, it should be replaced.
Secondary Air Box Cleaning
Caution: Only clean out if debris has fallen down the air tube.
1. The secondary air box access is located on the bottom rear of the fireplace and can be accessed for
cleaning by removing the two bottom center bricks inside the fireplace (Figure 2). This will expose the
access cover.
2. Remove the screws securing the access cover to the firebox bottom. Inspect airbox for debris. If debris is
present, carefully use a vacum to suck debris through the hole in the firebox bottom.
3. Replace the cover plate and the bricks.
Baffle tube
Figure 1: Baffle tube.
Access
cover
Figure 2: Draft box clean
out cover.
13
100001385_071118-40
FP25
Содержание FP25
Страница 39: ...39 100001385_071118 40 FP25...