DO NOT place any facing materials inside the facing edge/stop. This will prevent proper airflow into the unit
as well as preventing removal of the rear surround to service the blowers.
Only non combustible materials can be used in the area;
• Extending from the outer edge of the door out 11 1/2" [292mm],
• Under the door, down to the floor.
• Above the Heat Exchanger's air deflector up to a minimum of 16" [406mm].
Mantel and Finishing Clearances
11 1/2”
[292mm]
16” [406mm]
11 1/2”
[292mm]
NO
COMBUSTIBLES
Allowed in this area
Figure 29: FP25 Mantle and Pillar.
Mantel Clearances and Dimensions
Minimum distance to the underside of the Mantel (max 12” deep) from the top of the
Heat Exchanger Air Deflector.
16” (406mm)
Minimum distance to the adjacent wall from the side of the fireplace door.
22” (560mm)
Minimum distance to the Mantel side facing (Max 4” deep) from the side of the fire-
place door.
11 1/2” (292mm)
**Raised hearth must be completly constructed of non-combustible materials**
Minimum width of floor protection from side of door opening.
8” (200mm)
Minimum depth of non-combustible ember protector: from the front of the fireplace.
16 1/2” (420mm)
32
100001385_071118-40
FP25