The FP25 blowers must be connected to 120 VAC house hold electrical system. Connect the blower circuit to
a wall switch or fan speed controller.(not supplied)
Insert the Romex 14/2 wire, or equivalent, into the unit through the strain relief located in the junction box on
the right hand side of the support base (Figure 14).
Connect the wiring as shown in the wiring diagram (Figure 16) to the wires located in the junction box. See
"Blower Replacement" on page 14.
All electrical connections should be performed by a certified/licensed electrician.
Convection Blower Wiring
Electrical
box
Figure 15: Outside air opening.
Neutral
Line
Ground
Blowers
Temp
Switch
Junction Box
From Wall
Switch/Fan
controller
Electrical Rating : 115 V, 60 Hz, 1.1A
Figure 16: FP Wiring Diagraml.