110
S Y M P T O M
PROBABLE CAUSE
SOLUTION
MicroChine speed is grossly
inaccurate.
MicroChine is overloaded.
Status LED is illuminated
Yellow in color.
Disengage MicroChine from workpiece.
Resume operation exerting less
pressure on handpiece.
Defective handpiece.
Replace handpiece.
Multifunction pcb defective or
requires adjustment.
Contact PACE Service Department.
Pik-Vac has insufficient
vacuum.
"Low Pressure" output on
power source rear panel is
obstructed.
Remove obstruction.
Pulse Heat handpieces do
not heat. Pulse Heat LED is
illuminated Green in color.
Loose connection at Pulse
Heat Outputs or handpiece
connector.
Tighten connections.
Multifunction pcb defective.
Contact PACE Service Department.
Foot Pedal does not
operate in PH, PP, MP or
PD position.
Foot pedal connected to
incorrect receptacle.
Connect foot pedal to receptacle on
rear panel of power source marked
"FOOT PEDAL".
Multifunction pcb defective.
Contact PACE Service Department.
Broken wire in harness.
Contact PACE Service Department.
POWER SOURCE CONT'D
Table 7. Corrective Maintenance, Power Source Cont'd
Содержание PRC 2000
Страница 1: ...1 SYSTEM OPERATION MAINTENANCE MANUAL PRC 2000 SYSTEMS ...
Страница 2: ...2 ...
Страница 3: ...3 MANUAL NO 5050 0313 REV G ...
Страница 17: ...17 Figure 6 Thermal Management Center ...
Страница 23: ...23 Figure 12 Pik And Paste Section ...
Страница 74: ...74 ...
Страница 95: ...95 Figure 122 Pulse Plate Set Up ...
Страница 96: ...96 ...
Страница 102: ...102 ...
Страница 111: ...111 ...
Страница 119: ...119 ...