40
DIGITAL READOUT OPERATION
7. The Digital Readout provides a 3 digit display of the
Current Channel temperature information. The Digital
Readout will show the Set Tip Temperature in the
TIP
SET
Mode, Tip Offset Constants in
TIP
OFFSET
Mode and the True (Operating Tip) Temperature in the
Temperature Display Mode (normal operation).
PANEL CONTROLS
8. With three handpieces connected to the system (no
auxiliary accessories connected), press the
CH
SELECT
Key several times to observe the lighting of
the
CH 1
,
CH 2
&
CH 3
LEDS. Each subsequent
pressing will turn an LED off and turn the next Active
Channels’ LED on. The illumination sequence will be
CH 1
to
CH 2
to
CH 3
and then back to
CH 1
.
Unplug any one of the handpieces and repeat. The
LED of any Inactive Channel (no attached handpiece)
will not light. The next Active Channel in sequence
will light. NOTE:
CH 1
LED will illuminate and “
E-1
”
will be displayed on the Digital Readout if there are
no Active Channels. If all channels were set to
“OFF”, the Digital Readout will display “OFF”.
9. Press the
TIP OFFSET
Key. The
TIP OFFSET
LED
will blink and the Digital Readout will display the TIP
OFFSET
CONSTANT for the Current Channel. As
received from the factory, the Digital Readout will
display “3” FOR °C (“6” FOR °F). If the
TIP OFFSET
Key is immediately pressed again, or if no other
operation occurs within 5 seconds, the LED will turn
off and the Digital Readout will revert to the
Temperature Display Mode (normal operation).
Figure 28. Digital Readout "888"
Figure 29. TMC Front Panel
Figure 30. Tip Offset Key Activation
Содержание PRC 2000
Страница 1: ...1 SYSTEM OPERATION MAINTENANCE MANUAL PRC 2000 SYSTEMS ...
Страница 2: ...2 ...
Страница 3: ...3 MANUAL NO 5050 0313 REV G ...
Страница 17: ...17 Figure 6 Thermal Management Center ...
Страница 23: ...23 Figure 12 Pik And Paste Section ...
Страница 74: ...74 ...
Страница 95: ...95 Figure 122 Pulse Plate Set Up ...
Страница 96: ...96 ...
Страница 102: ...102 ...
Страница 111: ...111 ...
Страница 119: ...119 ...