106
POWER SOURCE
S Y M P T O M
PROBABLE CAUSE
S O L U T I O N
Digital Readout is blank.
No functions on system.
Blown Fuse (F1)
Replace Fuse F1 located on rear of
Power Source in the AC Receptacle.
Digital Readout is blank.
Some functions work.
Low AC line voltage.
Check line voltage.
Microprocessor pcb defect.
Contact PACE Service Department.
E-1 displayed on Digital
Readout.
All Channels are unplugged
on Thermal Mgmt. Center.
Plug handpiece into CH 1, CH 2 OR CH
3.
Open sensor in handpiece.
Refer to handpiece Operation Manual
for Corrective Maintenance procedures.
E-2, E-3 or E-4 displayed on
Digital Readout.
Defective heater assembly
in handpiece.
Unplug all handpieces. Plug
handpieces back in one at a time.
When defective handpiece is
connected, "E" code will be displayed.
Refer to handpiece Operation Manual.
No heat on handpiece(s) at
Thermal Management Center.
Open heater.
Refer to handpiece Operation Manual.
Blown 12 Amp Fuse.
Replace 12 amp Fuse located on rear
of Power Source.
Handpieces connected to
AUX receptacles. SP & SX
series handpieces are not
AUX compatible.
Disconnect incompatible handpieces
from AUX Receptacles. Connect to
Power Receptacles on front panel.
Damaged Power
Receptacle.
Contact PACE Service Department.
System overload. Check for
defective handpiece.
Disconnect defective handpiece.
220 Volt version only: Overtemp cutout
in transformer may open. Allow
transformer to cool.
Microprocessor pcb defect.
Contact PACE Service Department.
Table 7. Corrective Maintenance, Power Source
Содержание PRC 2000
Страница 1: ...1 SYSTEM OPERATION MAINTENANCE MANUAL PRC 2000 SYSTEMS ...
Страница 2: ...2 ...
Страница 3: ...3 MANUAL NO 5050 0313 REV G ...
Страница 17: ...17 Figure 6 Thermal Management Center ...
Страница 23: ...23 Figure 12 Pik And Paste Section ...
Страница 74: ...74 ...
Страница 95: ...95 Figure 122 Pulse Plate Set Up ...
Страница 96: ...96 ...
Страница 102: ...102 ...
Страница 111: ...111 ...
Страница 119: ...119 ...