107
S Y M P T O M
PROBABLE CAUSE
SOLUTION
Foot Pedal does not activate
vacuum or air pressure for
Thermal Management Center.
Foot Pedal connected to
incorrect receptacle for
Thermal Mgt. Center motor
pump activation.
Connect Foot Pedal to any spare AUX
Power Receptacle on Thermal
Management Center.
Defective motor pump.
Contact PACE Service Department.
Microprocessor pcb defect.
Contact PACE Service Department.
Keys on Thermal
Management Center don't
function properly.
Key caps binding.
Clean and/or adjust Key caps.
Display pcb misaligned or
defective.
Contact PACE Service Department.
Microprocessor pcb
defective.
Contact PACE Service Department.
Cannot adjust Offset or Set
Tip Temperature on Thermal
Management Center. Digital
Readout displays "P--".
System is requesting
Password entry.
Enter Password.
Operator forgot Password.
Clear Password. See "Clearing a
Password" instructions.
Digital Readout on Thermal
Management Center is grossly
inaccurate.
System out of calibration.
Wait 4 minutes for system to perform
automatic internal recalibration.
Shorted handpiece or
accessory connected to
AUX or Power Receptacle.
Disconnect handpieces and
accessories. Repair defective
handpiece or accessory.
Defective Microprocessor
pcb.
Contact PACE Service Department.
Table 7. Corrective Maintenance, Power Source Cont'd
Содержание PRC 2000
Страница 1: ...1 SYSTEM OPERATION MAINTENANCE MANUAL PRC 2000 SYSTEMS ...
Страница 2: ...2 ...
Страница 3: ...3 MANUAL NO 5050 0313 REV G ...
Страница 17: ...17 Figure 6 Thermal Management Center ...
Страница 23: ...23 Figure 12 Pik And Paste Section ...
Страница 74: ...74 ...
Страница 95: ...95 Figure 122 Pulse Plate Set Up ...
Страница 96: ...96 ...
Страница 102: ...102 ...
Страница 111: ...111 ...
Страница 119: ...119 ...