PASSWORD
A password feature of the
THERMAL MANAGEMENT CENTER
which, when activated, will prevent
unauthorized alteration of stored System and Channel features listed in Table 1 "Factory Settings". If a
password has been installed, "P - - " will appear on the Digital Readout to prevent the operator from
changing any of the stored settings. Entry of the correct password at this point will allow the operator to
proceed with desired changes. Listed following are procedures for all password entry, change and removal
operations.
INITIAL INSTALLATION OF A PASSWORD
1. Place the
POWER
Switch in the OFF ("0") position.
2. Press and hold the
TIP SET
and the
°F
/
°C
Keys down.
3. Place
POWER
Switch in the ON (“1”) position. All the
THERMAL MANAGEMENT CENTER
LEDs will
illuminate. The Digital Readout will read “888” and
change to read “1 - 0”. This number may be different on
your unit.
Figure 50. Enter Password Mode
Figure 49. Power Off
Figure 51. Digital Readout "888"