97
PULSE HEAT
Located on the extreme left side of the PRC 2000 system, the
PULSE HEAT
section features a power
output which provides controlled temperature ramp-up to solder reflow and rapid cool down. This
controlled temperature ramp-up helps reduce the risk of thermal shock damage to components and
substrates in combination with other measures such as preheating with the PACE HotSpot. A variety of
rapid connect/disconnect handpieces allow the operator to perform many different SMD removal/
replacement tasks which may be required for any particular repair process. Refer to the “Capabilities”
portion of this manual for a complete description of
PULSE HEAT
functions.
SET-UP
1. Install the Redi-Rak handpiece storage holder
onto the top of the system power source.
Complete installation instructions are included
with the Redi-Rak.
2. Insure that the foot pedal connector plug has
been connected to the
FOOT PEDAL
Receptacle located on the rear panel of the
power source.
3. Set the
PULSE HEAT
Output Control to “0”.
Figure 124. Pulse Heat Control
Figure 123. Foot Pedal Connection
Содержание PRC 2000
Страница 1: ...1 SYSTEM OPERATION MAINTENANCE MANUAL PRC 2000 SYSTEMS ...
Страница 2: ...2 ...
Страница 3: ...3 MANUAL NO 5050 0313 REV G ...
Страница 17: ...17 Figure 6 Thermal Management Center ...
Страница 23: ...23 Figure 12 Pik And Paste Section ...
Страница 74: ...74 ...
Страница 95: ...95 Figure 122 Pulse Plate Set Up ...
Страница 96: ...96 ...
Страница 102: ...102 ...
Страница 111: ...111 ...