D-160TS-7-E
37
Name
Description / Range
Unit
Display
Sampling time
If no flow pulse input is detected during the set duration
(second), instant flow rate reads "0". / 1 to 999
sec
—
Sample cycle number
If instant flow rate varies considerably, set larger value to reduce
variation. / 1 to 999
—
—
Flow average count
Moving average setting of instant flow rate calculation. / 1 to 20
—
—
Flow rate setting
Name
Description / Range
Unit
Display
Trigger level
Trigger level setting of vortex signal. / 1 to 2800
mVp-p
—
Trigger level
Name
Description / Range
Unit
Display
B const
B constant setting of sensor. / 0 to 65535
—
—
R0
Reference resistance setting of sensor. (kΩ) / 0 to 65.535
kΩ
—
T0
Reference temperature setting of sensor. (
℃
) / -30.0 to 130.0
℃
—
Sensor
Name
Description / Range
Unit
Display
Adjust voltage
Target setting for sensor voltage adjusting. / 4 to 22
V
—
Vset
Target voltage for sensor voltage control. / 0 to 30
V
—
Sensor voltage control
Name
Description / Range
Unit
Display
Lowcut Pulse function
Digital filter setting for unfactored pulse output.
ON: Digital filter enabled
OFF: Digital filter disabled
—
—
Memory count
Pulse output is generated when periodic pulse input below
[Low cut lower period] exceeds this setting. / 1 to 8192
—
—
Low cut upper period
Pulse output is discontinued when periodic pulse input
exceeds this setting. / 0.5 to 5000
ms
—
Low cut lower period
Pulse output is generated when periodic pulse input below [Low
cut lower period] exceeds this setting. / 0.5 to 5000
ms
—
Pulse digital filter
Name
Description / Range
Unit
Display
Maximum band
Filter upper band setting.
/ 1 to 7 (Maximum band>Minimum band)
—
—
Minimum band
Filter lower band setting.
/ 2 to 8 (Maximum band>Minimum band)
—
—
Sampling frequency
Select based on flow range. / Fast, Slow
—
—
Analog filter circuit
Select based on meter size. / 0, 1, 2, 3
—
—
Filter setting