Parameter description
Default
Parameter description
Default
Parameter description
Default
Status output logic setting.
See section 14. STATUS OUTPUT for detail
Full scale (max. measuring flow rate) of % flow rate can be changed.
※Unit: m
3
/h (standard setting)
Meter factor (L/Pulse) setting.
Min. measuring flow rate can be changed. Flow rate below this setting will not be measured. Effective for
the prevention of erroneous output due to zero flow fluctuation (noise). ※Unit: m
3
/h (standard setting)
Hysteresis width setting of High/Low alarm.
※Unit: m
3
/h (standard setting)
Dead time duration setting of High/Low alarm.
※Unit: second
Low alarm setting. Alarm output is generated when flow rate is below this setting.
※Unit: m
3
/h (standard setting)
High alarm setting. Alarm output is generated when flow rate is above this setting.
※Unit: m
3
/h (standard setting)
Password setting. To enable the set password, password function must be "ON". Be careful not to
forget the password.
Password function enable/disable selection. When "ON" is selected, password input will be
required before entering the setting menu screen to prevent unwanted parameter changes.
Function assignment setting of status output.
See section 14. STATUS OUTPUT for detail
OPEn
Off
0000
non
non
1.0
Parameter description
Default
Function assignment setting of flow alarm.
See section 15. HIGH/LOW ALARM for detail
Varies with
customer spec.
Varies with
customer spec.
Varies with
customer spec.
Varies with
customer spec.
5
0.0000E+00
0
※1 Operate while display is blinking.
※2 Displayed only if password function is valid.
※3 Not displayed if [AL.Fun] is [non].
[SEL]
[SEL Hold]
[ENT Hold]
Transition after entering password
【Upper LCD】Mode selection
% flow rate
display
Setting Mode
Main parameter
Sub-parameter
Sub-parameter
Sub-parameter
Sub-parameter
Enter password
Password setting
00−00
Password setting
00−02
Full scale flow rate
01−01
Meter factor
01−03
Status output mode
02−01
Status output assign
02−02
Pulse output ON width
02−03
Flow alarm func. assign
03−01
Alarm dead time
03−05
Alarm hysteresis
03−04
Alarm low limit
03−03
Alarm high limit
03−02
Lowcut flow rate
01−02
Password selection
00−01
Flow rate setting
01−00
Output selection
02−00
Flow alarm setting
03−00
**%
modE
PAS.wd
Pw.oPt
Pw.oPt
Pw.SEt
FL.FSC
m.FACt
S.modE
P.wid
AL.Fun
AL.Hi
AL.nF.t
AL.Hys
AL.Lo
S.FunC
Lo.Cut
FLow
OutPt
ALArm
※1
※1
※2
%
※3
※3
※3
※3
Pulse width setting. ※Unit: msec
Continued on next page
13. MENU TREE