DGS-7084GCP-AIO_S SERIES User’s Manual
ORing Industrial Networking Corp
85
hexadecimal).
ARP: Only ARP frames can match this ACE. Notice the ARP frames
won't match the ACE with Ethernet type.
IPv4: Only IPv4 frames can match this ACE. Notice the IPv4 frames
won't match the ACE with Ethernet type.
Action
Specify the action to take with a frame that hits this ACE.
Permit: The frame that hits this ACE is granted permission for the
ACE operation.
Deny: The frame that hits this ACE is dropped.
Rate Limiter
Specify the rate limiter in number of base units. The allowed range is
1 to 15. Disabled indicates that the rate limiter operation is disabled.
Port Copy
Frames that hit the ACE are copied to the port number specified
here. The allowed range is the same as the switch port number
range. Disabled indicates that the port copy operation is disabled.
Logging
Specify the logging operation of the ACE. The allowed values are:
Enabled: Frames matching the ACE are stored in the System Log.
Disabled: Frames matching the ACE are not logged.
Please note that the System Log memory size and logging rate is
limited.
Shutdown
Specify the port shut down operation of the ACE. The allowed values
are:
Enabled: If a frame matches the ACE, the ingress port will be
disabled.
Disabled: Port shut down is disabled for the ACE.
Counter
The counter indicates the number of times the ACE was hit by a
frame.
Label
Description