DGS-7084GCP-AIO_S SERIES User’s Manual
ORing Industrial Networking Corp
137
R.M. indicator (R.M.)
Green : indicate system operated in O-Ring Master mode
Ring indicator (Ring)
Green : indicate system operated in O-Ring mode
Fault indicator (Fault)
Amber : Indicate unexpected event occurred
10/100/1000Base-T(X) RJ45 port
indicator
Green for port Link/Act. Amber for Duplex/Collision
SFP Fiber port indicator
Green for port Link/Act.
Bypass LED indicators
Power indicator (Power 1/2)
Green : power LED x 2
Power fail indicator (Power Fail)
Amber : indicate bypass power fail status
Bypass enable status indicate
(Bypass)
Green : indicate bypass function in enable mode
Bypass normal status indicate
(Normal)
Green : indicate bypass function in normal (disable) mode
Fault contact
Relay
Relay output to carry capacity of 1A at 24VDC
Power
Redundant Input power
Dual 100~240V AC power inputs in single power socket
Power consumption (Typ.)
TBD
Overload current protection
Present
Physical Characteristic
Enclosure
IP-30
Dimension (W x D x H)
300 (W) x 165 (D) x 88 (H) mm
Weight (g)
2.3 Kg
Environmental
Storage Temperature
-40 to 85
o
C (-40 to 185
o
F)
Operating Temperature
-40 to 70
o
C (-40 to 158
o
F)
Operating Humidity
5% to 95% Non-condensing
Regulatory approvals
EMI
FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS),
EN61000-4-8, EN61000-4-11
Shock IEC60068-2-27
Free Fall
IEC60068-2-32
Vibration IEC60068-2-6
Safety EN60950-1
Warranty