1.
Set the step angle to full step.
Set the step angle
switch (F/ H) to “ ON ”.
33
Motor operating current
1.
Set the step angle to full step.
Set the step angle
switch (F/ H) to “ ON ”.
2.
Disable the automatic current-cutback
function.
Set the automatic
current-cutback
function switch
(A.C.D.) to “ OFF ”.
OFF
4
2
1
3
F/
H
1P/2P
24/36V
ACD
ON :
Full step
ON
OFF
F/H
Be sure to adjust the current to the motor’s rated
current or below.
The sum of two DC-ammeter readings indicates
the current per motor phase.
3.
Turn on the power supply.
Wait until the motor reaches its operating current.
4.
Manipulate the potentiometer for adjusting
the motor operating current (RUN VR).
Adjust the potentiometer using an insulated
screwdriver.
OFF
4
2
1
3
F/
H
1P/2P
24/36V
ACD
OFF :
Disable the automatic
current-cutback function
ON
OFF
A.C.D.
Motor standstill current
2.
Enable the automatic current-cutback
function.
Set the automatic
current-cutback
function switch
(A.C.D.) to “ ON ”.
OFF
4
2
1
3
F/
H
1P/2P
24/36V
ACD
ON :
Full step
ON
OFF
F/H
3.
Turn on the power supply.
Wait until the motor reaches its standstill current.
4.
Manipulate the potentiometer for adjusting
the motor standstill current (STOP VR).
Adjust the potentiometer using an insulated
screwdriver.
The sum of two DC ammeter readings indicates
the current per motor phase.
Be sure to adjust the current to 40 percent of the
motor’s rated current or below.
5.
Turn off the power supply.
This completes the adjustment of the motor
standstill current.
OFF
4
2
1
3
F/
H
1P/2P
24/36V
ACD
ON :
Enable the automatic
current-cutback function
ON
OFF
A.C.D.
RUN
VR
STOP
VR
RUN VR
5.
Turn off the power supply
.
Example:
DC ammeter reading 0.5 A 0.45 A
Output current per phase 0.95 A
When a tester is used, the voltage shown on the
tester corresponds to the current per motor phase.
Example:
Tester reading 0.95 V
Output current per phase 0.95 A
This completes the adjustment of the motor
operating current.
6.
Set the automatic current-cutback function
switch (A.C.D.) to
“ ON ” again.
OFF
4
2
1
3
F/
H
1P/2P
24/36V
ACD
ON :
Enable the automatic
current-cutback function
ON
OFF
A.C.D.
RUN
VR
STOP
VR
STOP VR