Insert the Sun Blade X4-2B Server Module Into a
Chassis
Locate a blank blade slot in the Sun Blade 6000 modular system chassis.
http://www.oracle.com/goto/SB6000/docs
Remove a slot filler panel.
a. Pinch together the ends of the ejector arm handle to unlock the slot filler panel.
b. Rotate the lever out to the open position.
c.
Eject the filler panel.
d. Keep the filler panel for later use.
Caution –
Chassis shutdown hazard. Do not operate the chassis with empty slots for more than
60 seconds. Always insert a filler panel into an empty slot. If you are not installing a server
module into a slot, do not remove a slot filler panel. The slot filler panel is required to meet FCC
standards for electromagnetic interference (EMI).
Remove the rear cover from the server module rear panel midplane connector.
See
“Rear Panel Features” on page 11
for the location of the rear cover.
1
2
3
3. Insert the Server Module Into a Chassis
33