4-28
Sun Fire X4240 Server Service Manual • September 2010
a. Power off the server.
See
Section 2.5, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.5, “Powering Off the Server” on page 2-4
.
c. Remove the server from the rack.
See
Section 2.7, “Removing a Server From the Rack” on page 2-8
..
d. Attach an antistatic wrist strap.
See
Section 2.8, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-10
.
e. Remove the top cover.
See
Section 2.9, “Removing the Top Cover” on page 2-12
.
2. Remove the air duct.
See
Section 4.2.1, “Removing the Air Duct” on page 4-11
.
3. Remove the PCIe cards and risers.
See
Section 4.3.1, “Removing a PCIe Riser” on page 4-15
. Note the location of
expansion cards in the PCIe risers.
4. Disconnect the power distribution board ribbon cable. (
FIGURE 4-14
[1] )
See
Section 5.8.3, “Removing a PDB Cable” on page 5-27
.
5. Disconnect the drive data cables.
See
Section 1.2.2, “System Cables” on page 1-5
.
Caution –
The drive data cables are delicate. Ensure that they are safely out of the
way when servicing the motherboard.
6. Remove the 4 screws that secure the motherboard to the bus bar. [2]
Use a No. 2 Phillips screwdriver.
7. Lift the motherboard tray out of the chassis. [3]
Move the motherboard carefully. Gently slide the motherboard to the rear and
carefully lift it upward.
8. If you are replacing the motherboard only, remove the processors, as required.
See
Section 4.8.2, “Removing a Processor” on page 4-37
.
9. Place the motherboard assembly on an antistatic mat.
Содержание Sun Fire X4240
Страница 1: ...Sun Fire X4240 Server Service Manual Part No 820 3835 14 September 2010 Revision A ...
Страница 9: ...Contents ix Index Index 1 ...
Страница 10: ...x Sun Fire X4240 Server Service Manual September 2010 ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 FIGURE 2 6 Removing the Top Cover ...
Страница 40: ...2 14 Sun Fire X4240 Server Service Manual September 2010 ...
Страница 62: ...3 22 Sun Fire X4240 Server Service Manual September 2010 FIGURE 3 15 Installing the DVD USB Module ...
Страница 76: ...4 14 Sun Fire X4240 Server Service Manual September 2010 FIGURE 4 7 Installing the Air Duct ...
Страница 83: ...Chapter 4 Servicing Motherboard Components 4 21 FIGURE 4 11 Removing a PCIe Card ...
Страница 139: ...Chapter 5 Servicing Infrastructure Boards and Components 5 29 FIGURE 5 17 Installing a PDB Cable ...
Страница 140: ...5 30 Sun Fire X4240 Server Service Manual September 2010 ...
Страница 190: ...Index 4 Sun Fire X4240 Server Service Manual September 2010 T Top Fan LED 3 11 3 14 U USB ports 1 2 X XOption CPU 4 41 ...