Chapter 2
Preparing to Service the System
2-11
Caution –
You must disconnect both power supplies before servicing any of the
components documented in this chapter.
2.8.1.1
Using an Antistatic Wrist Strap
Wear an antistatic wrist strap and use an antistatic mat when handling components
such as drive assemblies, circuit boards, or PCI cards. When servicing or removing
server components, attach an antistatic strap to your wrist and then to a metal area
on the chassis. Following this practice equalizes the electrical potentials between you
and the server.
Note –
An antistatic wrist strap is not included in the accessory kit for the Sun Fire
X4240. However, antistatic wrist straps are still included with options.
2.8.1.2
Using an Antistatic Mat
Place antistatic-sensitive components such as motherboards, memory, and other
PCBs on an antistatic mat.
2.8.2
Antistatic Handling Procedure
1. Prepare an antistatic surface to set parts on during the removal, installation, or
replacement process.
Place antistatic-sensitive components such as the printed circuit boards on an
antistatic mat. The following items can be used as an antistatic mat:
■
Antistatic bag used to wrap a Sun replacement part
■
Sun antistatic mat, part number 250-1088
■
A disposable antistatic mat (shipped with some replacement parts or optional
system components)
2. Attach an antistatic wrist strap.
When servicing or removing server components, attach an antistatic strap to your
wrist and then to a metal area on the chassis.
Содержание Sun Fire X4240
Страница 1: ...Sun Fire X4240 Server Service Manual Part No 820 3835 14 September 2010 Revision A ...
Страница 9: ...Contents ix Index Index 1 ...
Страница 10: ...x Sun Fire X4240 Server Service Manual September 2010 ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 FIGURE 2 6 Removing the Top Cover ...
Страница 40: ...2 14 Sun Fire X4240 Server Service Manual September 2010 ...
Страница 62: ...3 22 Sun Fire X4240 Server Service Manual September 2010 FIGURE 3 15 Installing the DVD USB Module ...
Страница 76: ...4 14 Sun Fire X4240 Server Service Manual September 2010 FIGURE 4 7 Installing the Air Duct ...
Страница 83: ...Chapter 4 Servicing Motherboard Components 4 21 FIGURE 4 11 Removing a PCIe Card ...
Страница 139: ...Chapter 5 Servicing Infrastructure Boards and Components 5 29 FIGURE 5 17 Installing a PDB Cable ...
Страница 140: ...5 30 Sun Fire X4240 Server Service Manual September 2010 ...
Страница 190: ...Index 4 Sun Fire X4240 Server Service Manual September 2010 T Top Fan LED 3 11 3 14 U USB ports 1 2 X XOption CPU 4 41 ...