6-2
Sun Fire X4240 Server Service Manual • September 2010
6.1
Installing the Top Cover
If you removed the top cover, perform the following steps to replace it:
1. Place the top cover on the chassis.
Set the cover down so that it hangs over the rear of the server by about an inch
(25.4 mm).
2. Slide the top cover forward until it seats (
FIGURE 6-1
).
3. Close the fan cover and engage the fan cover latches.
Caution –
If the top cover is not installed correctly, and the cover is not completely
closed, the server will not power on.
FIGURE 6-1
Installing the Top Cover