Chapter 4
Servicing Motherboard Components
4-3
c. Slide the server out of the rack.
See
Section 2.6, “Extending the Server to the Maintenance Position” on
page 2-6
.
d. Attach an antistatic wrist strap.
See
Section 2.8, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-10
.
e. Remove the top cover.
See
Section 2.9, “Removing the Top Cover” on page 2-12
.
2. Press and hold the Remind button to identify which DDR2 DIMM is faulty.
(
FIGURE 4-1
)
3. Note the location of faulty DDR2 DIMMs.
Faulty DDR2 DIMMs are identified with a corresponding amber LED on the
motherboard.
4. Ensure that all DDR2 DIMMs are seated correctly in their slots.
If re-seating the DDR2 DIMM does not fix the problem, remove and replace the
faulty DDR2 DIMM.
Note –
Refer to the
Sun Fire X4140, X4240, and X4440 Servers Diagnostics Guide
for
more information about DIMM System Event Log (SEL) messages.
Содержание Sun Fire X4240
Страница 1: ...Sun Fire X4240 Server Service Manual Part No 820 3835 14 September 2010 Revision A ...
Страница 9: ...Contents ix Index Index 1 ...
Страница 10: ...x Sun Fire X4240 Server Service Manual September 2010 ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 FIGURE 2 6 Removing the Top Cover ...
Страница 40: ...2 14 Sun Fire X4240 Server Service Manual September 2010 ...
Страница 62: ...3 22 Sun Fire X4240 Server Service Manual September 2010 FIGURE 3 15 Installing the DVD USB Module ...
Страница 76: ...4 14 Sun Fire X4240 Server Service Manual September 2010 FIGURE 4 7 Installing the Air Duct ...
Страница 83: ...Chapter 4 Servicing Motherboard Components 4 21 FIGURE 4 11 Removing a PCIe Card ...
Страница 139: ...Chapter 5 Servicing Infrastructure Boards and Components 5 29 FIGURE 5 17 Installing a PDB Cable ...
Страница 140: ...5 30 Sun Fire X4240 Server Service Manual September 2010 ...
Страница 190: ...Index 4 Sun Fire X4240 Server Service Manual September 2010 T Top Fan LED 3 11 3 14 U USB ports 1 2 X XOption CPU 4 41 ...