5-6
Sun Fire X4240 Server Service Manual • September 2010
c. Remove the server from the rack.
See
Section 2.7, “Removing a Server From the Rack” on page 2-8
.
d. Attach an antistatic wrist strap.
See
Section 2.8, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-10
.
e. Remove the top cover.
See
Section 2.9, “Removing the Top Cover” on page 2-12
.
2. If you are servicing the drives backplane, remove all drives.
See
Section 3.2.4, “Removing a Hard Drive or SSD” on page 3-5
.
Note –
Make a note of the drive locations before removing them from the system.
You will need to install the drives in the correct locations when reassembling the
system.
3. If you are servicing the drives backplane, remove the DVD/USB module.
See
Section 3.5.1, “Removing the DVD/USB Module” on page 3-20
.
4. Remove the fan modules.
See
Section 3.3.4, “Removing a Fan Module” on page 3-12
.
5. Remove the fan power boards.
See
Section 5.1.1, “Removing a Fan Power Board” on page 5-2
.
6. Remove the No. 2 Phillips screws securing the drives cage to the chassis.
(
FIGURE 5-3
[1] and [2])
Two screws secure the disk cage to each side of the chassis.
7. Slide the drives cage forward to disengage the backplane from the paddle cards.
(
FIGURE 5-3
[3])
8. Lift the drives cage up and disconnect the drives data cables. (
FIGURE 5-3
[4])
Press the connector release button to release the cable.
9. Set the drive cage on an antistatic mat.
Содержание Sun Fire X4240
Страница 1: ...Sun Fire X4240 Server Service Manual Part No 820 3835 14 September 2010 Revision A ...
Страница 9: ...Contents ix Index Index 1 ...
Страница 10: ...x Sun Fire X4240 Server Service Manual September 2010 ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 FIGURE 2 6 Removing the Top Cover ...
Страница 40: ...2 14 Sun Fire X4240 Server Service Manual September 2010 ...
Страница 62: ...3 22 Sun Fire X4240 Server Service Manual September 2010 FIGURE 3 15 Installing the DVD USB Module ...
Страница 76: ...4 14 Sun Fire X4240 Server Service Manual September 2010 FIGURE 4 7 Installing the Air Duct ...
Страница 83: ...Chapter 4 Servicing Motherboard Components 4 21 FIGURE 4 11 Removing a PCIe Card ...
Страница 139: ...Chapter 5 Servicing Infrastructure Boards and Components 5 29 FIGURE 5 17 Installing a PDB Cable ...
Страница 140: ...5 30 Sun Fire X4240 Server Service Manual September 2010 ...
Страница 190: ...Index 4 Sun Fire X4240 Server Service Manual September 2010 T Top Fan LED 3 11 3 14 U USB ports 1 2 X XOption CPU 4 41 ...