1-2
Sun Fire X4240 Server Service Manual • September 2010
The product features are listed in
TABLE 1-1
.
TABLE 1-1
Sun Fire X4240 Server System Features
Feature
Description (Sun Fire X4240)
Processor
AMD64 Opteron Socket F [1207] (1MByte L2 cache per processor chip).
Supports Dual and Quad core.
Memory
• 8 DDR-2 DIMM slots per socket. Up to 800 MHz memory speeds
depending upon processor type and memory configuration.
• PC2-4200R 533 MHz registered DIMMs with ECC
• PC2-5300R 667 MHz registered DIMMs with ECC
• PC2-6400R 800 MHz registered DIMMs with ECC
• 1 GB, 2 GB, 4 GB, or 8 GB per DIMM
• See
Section 4.1.2, “DDR2 DIMM Guidelines” on page 4-4
.
Ethernet ports
4 ports, 10/100/1000 Mbps, auto-negotiating through two separate
controllers
Internal drives
• SAS (up to 16) or SATA (up to 8 SSD) disk drives.
• Up to 16 SFF SAS 73-GB or 146-GB 2.5-inch form factor drives.
• Support for hardware-embedded RAID 0 (striping) and RAID 1
(mirroring)
• Optional RAID Levels 0, 1, IE, 5, 5EE, 6, 10, 50, and 60
Removable
media
1 slimline DVD drive, supporting CD-R/W, CD+R/W, DVD-R/W,
DVD+R/W
USB ports
5 USB 2.0 ports: 2 in front, 2 in rear, plus 1 internal USB port
Service ports
• 1 RJ-45 serial management port (SER MGT) (default connection to
access service processor)
• 1 10-MB network management port (NET MGT) (to access service
processor)
• HD15 VGA video port
Cooling
• 6 hot-swappable system fan modules (2 fans per module)
• An air duct facilitates processor/memory airflow
PCI interfaces
6 standard low-profile PCIe slots on three riser boards (1 -x4, 4 - x8 and 1
- x4 electrical / 5 - x16 and 1 - x8 mechanical)
See
Section 4.4.1, “Sun Fire X4240 PCIe Card Guidelines” on page 4-19
.
Power
• AC power: 100-240 VAC, 12-5A, 50-60Hz
• 1 or 2 hot-swappable 1050W power supply units (PSUs) to provide
N+N redundancy, with energy efficient design
Содержание Sun Fire X4240
Страница 1: ...Sun Fire X4240 Server Service Manual Part No 820 3835 14 September 2010 Revision A ...
Страница 9: ...Contents ix Index Index 1 ...
Страница 10: ...x Sun Fire X4240 Server Service Manual September 2010 ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 FIGURE 2 6 Removing the Top Cover ...
Страница 40: ...2 14 Sun Fire X4240 Server Service Manual September 2010 ...
Страница 62: ...3 22 Sun Fire X4240 Server Service Manual September 2010 FIGURE 3 15 Installing the DVD USB Module ...
Страница 76: ...4 14 Sun Fire X4240 Server Service Manual September 2010 FIGURE 4 7 Installing the Air Duct ...
Страница 83: ...Chapter 4 Servicing Motherboard Components 4 21 FIGURE 4 11 Removing a PCIe Card ...
Страница 139: ...Chapter 5 Servicing Infrastructure Boards and Components 5 29 FIGURE 5 17 Installing a PDB Cable ...
Страница 140: ...5 30 Sun Fire X4240 Server Service Manual September 2010 ...
Страница 190: ...Index 4 Sun Fire X4240 Server Service Manual September 2010 T Top Fan LED 3 11 3 14 U USB ports 1 2 X XOption CPU 4 41 ...