Servicing the Motherboard
The motherboard is the primary component of the server. The motherboard is located on a tray
at the bottom of the chassis. See
“Component Locations (Motherboard, Memory, and PCIe
.
Description
Links
Replace the faulty motherboard.
“Determine if the Motherboard Is Faulty” on page 227
“Remove the Motherboard” on page 230
“Install the Motherboard” on page 233
“Verify the Motherboard” on page 235
Remove the motherboard as part of another
component's service operation.
“Remove the Motherboard” on page 230
Install the motherboard as part of another
component's service operation.
“Install the Motherboard” on page 233
Determine if the motherboard is faulty.
“Determine if the Motherboard Is Faulty” on page 227
“Detecting and Managing Faults” on page 21
Related Information
■
“Identifying Components” on page 13
■
“Detecting and Managing Faults” on page 21
■
“Component Service Task Reference” on page 65
■
“Preparing for Service” on page 61
■
“Returning the Server to Operation” on page 247
Determine if the Motherboard Is Faulty
You must determine if the motherboard is faulty before you replace it.
1.
Check to see if any System Service Required LEDs are lit or flashing.
Servicing the Motherboard
227
Содержание netra X5-2
Страница 1: ...Netra Server X5 2 Service Manual Part No E53601 03 October 2016 ...
Страница 2: ......
Страница 12: ...12 Netra Server X5 2 Service Manual October 2016 ...
Страница 20: ...20 Netra Server X5 2 Service Manual October 2016 ...
Страница 59: ...Using the Server Fault Remind Button Detecting and Managing Faults 59 ...
Страница 60: ...60 Netra Server X5 2 Service Manual October 2016 ...
Страница 123: ...Remove a Power Supply 4 Press the release tab to the left and pull on the handle Servicing Power Supplies 123 ...
Страница 128: ...128 Netra Server X5 2 Service Manual October 2016 ...
Страница 144: ...144 Netra Server X5 2 Service Manual October 2016 ...
Страница 148: ...148 Netra Server X5 2 Service Manual October 2016 ...
Страница 154: ...154 Netra Server X5 2 Service Manual October 2016 ...
Страница 180: ...180 Netra Server X5 2 Service Manual October 2016 ...
Страница 210: ...210 Netra Server X5 2 Service Manual October 2016 ...
Страница 226: ...226 Netra Server X5 2 Service Manual October 2016 ...
Страница 266: ...266 Netra Server X5 2 Service Manual October 2016 ...
Страница 274: ...274 Netra Server X5 2 Service Manual October 2016 ...