Install a CPU
You hear a click, and the release button retracts.
6.
Position the tool over the CPU socket and lower it into place.
The triangle on the side of the tool aligns with pin 1 of the CPU socket.
Caution -
The tool must be level and flat onto the socket, not offset or angled.
7.
Press the release button on the tool to release the CPU into the socket.
Servicing CPUs
205